IX
Ventilation Requirement
It is best to allow free air circulation while the scope is in use. When using it in a benchtop or rack setting, provide
at least 10 cm clearance beside, above and behind the instrument for adequate ventilation.
WARNING
Inadequate ventilation may cause temperature increase which could damage the oscilloscope. So
please keep it well ventilated during operation.
AC Power Requirement
The power adapter operates with a single-phase, 100 to 240 Vrms (+/-10%) AC power at 50/60 Hz (+/-5%).
No manual voltage selection is required.
Depending on the type and number of options and accessories (probes, PC port plug-in, charging etc.), the
scope can consume up to 35 W while on AC power.
Note:
The power adapter automatically adapts to the AC line input within the following ranges:
Voltage Range:
90 - 264 Vrms
Frequency Range:
47 - 63 Hz
Please use the power cord and adapter provided by the manufacturer. Use of other adapters/chargers may
cause damage, fire, or injury.
WARNING
Electrical Shock Hazard!
Use of an adapter or power supply not specified by the manufacturer may cause personal injury.
To turn the oscilloscope completely off, unplug the power cord from the AC socket and remove the battery.
The battery should be removed from the scope when it is not to be used for an extended time.
Содержание OSC-9200
Страница 1: ...AEGIS Shaft Voltage Tester Handheld Digital Oscilloscope AEGIS OSC 9200...
Страница 18: ...3 Appearance and Dimensions mm Figure 1 Front View Figure 2 Side view...
Страница 44: ...29 Horizontal Control Contents u Horizontal Scale u Horizontal Delay u Roll Mode u Zoom Mode...
Страница 56: ...41 Figure 16 x Interpolation Figure 17 Sinx x Interpolation...
Страница 60: ...45 Figure 21 With Random Noise Normal Mode Figure 22 With Random Noise Average Mode...
Страница 101: ...86 l R W the type of a frame write or read l Data the value of the data Figure 42 I2C Decode List Display...
Страница 105: ...90...
Страница 116: ...101 l CRC the value of CRC Cyclic Redundancy Check field l ACK Acknowledgment bit Figure 57 CAN Decode List Displa...
Страница 135: ...120 Figure 75 Integral with Offset...
Страница 139: ...124 Figure 77 Measure Pulse Width...
Страница 146: ...131 Figure 83 Added the Measurement Note if the parameter does not match the measure condition it will display as...
Страница 190: ...175 DC Current Measurement AC Current Measurement...
Страница 204: ...info est aegis com www est aegis com...