![Aegis OSC-9200 Скачать руководство пользователя страница 138](http://html1.mh-extra.com/html/aegis/osc-9200/osc-9200_user-manual_2860410138.webp)
123
Make Cursor Measurements
1.
Press
Cursors
on the front panel to enter the CURSOR function menu.
2.
Press the
Mode
F key and set the cursor mode to
Manual
or
Track
.
3.
Press the
Source
F key, and then use the
Universal Knob
to select the desired source. Only
input channels, math waveforms, and reference waveforms are displayed as available for cursors.
4.
Press the
X Ref
and
Y Ref
F keys to set the reference of X cursors and Y cursors:
l
Position
: when the horizontal/vertical scale is changed, the X/Y cursors remain at the same
position on the display but the values change.
l
Delay/Offset
: when the horizontal/vertical axis is changed,
the value of X/Y cursors remain
fixed, but their positions on the screen change.
5.
To make cursor measurements:
l
To measure the horizontal time, use the
Universal Knob
to move the X1 and X2 cursors to
the desired place. If necessary, set the cursor type to
X2-X1
and move the X1 and X2 cursors
together.
l
To measure vertical voltage or current, use the
Universal Knob
to move the Y1 and Y2
cursors to desired place. If necessary, set the cursor type to “Y2-Y1” and move the Y1 and Y2
cursors together.
l
To adjust the transparency of the cursors message box, press
Display/Persist
, go to the
second page, press the
Transparence
(20% to 80%) F key, and then turn the
Universal Knob
to adjust the transparency to the desired value.
Cursor examples:
Use cursors to measure pulse width:
Содержание OSC-9200
Страница 1: ...AEGIS Shaft Voltage Tester Handheld Digital Oscilloscope AEGIS OSC 9200...
Страница 18: ...3 Appearance and Dimensions mm Figure 1 Front View Figure 2 Side view...
Страница 44: ...29 Horizontal Control Contents u Horizontal Scale u Horizontal Delay u Roll Mode u Zoom Mode...
Страница 56: ...41 Figure 16 x Interpolation Figure 17 Sinx x Interpolation...
Страница 60: ...45 Figure 21 With Random Noise Normal Mode Figure 22 With Random Noise Average Mode...
Страница 101: ...86 l R W the type of a frame write or read l Data the value of the data Figure 42 I2C Decode List Display...
Страница 105: ...90...
Страница 116: ...101 l CRC the value of CRC Cyclic Redundancy Check field l ACK Acknowledgment bit Figure 57 CAN Decode List Displa...
Страница 135: ...120 Figure 75 Integral with Offset...
Страница 139: ...124 Figure 77 Measure Pulse Width...
Страница 146: ...131 Figure 83 Added the Measurement Note if the parameter does not match the measure condition it will display as...
Страница 190: ...175 DC Current Measurement AC Current Measurement...
Страница 204: ...info est aegis com www est aegis com...