Table 3-14.
Management > Power over Ethernet > Interface Configuration and
Status (Continued)
Parameter
Description
Power Class
Displays the PD power classify level.
N/A - Specifies the PSE port is not delivering power.
Class-0 - Specifies PSE port power class level-0 is selected. The maximal out-
put power in PSE side is 30 Watts.
Class-1 - Specifies PSE port power class level-1 is selected. The maximal out-
put power in PSE side is 4 Watts.
Class-2 - Specifies PSE port power class level-2 is selected. The maximal out-
put power in PSE side is 7 Watts.
Class-3 - Specifies PSE port power class level-3 is selected. The maximal out-
put power in PSE side is 15.4 Watts.
Class-4 - Specifies PSE port power class level-4 is selected. The maximal out-
put power in PSE side is 30 Watts.
Power Consumption
Displays the power consumption of PSE port. The unit is watt.
Cumulative Power
Displays the power consumption summary of PSE port. The unit is KWH (kilowatt
Consumption
hour).
Current Consump-
Displays the current consumption summary of PSE port. The unit is mA.
tion
Detection Status
Displays the operation status of PSE port.
Disabled - Specifies PSE port is not delivering power.
Searching - Specifies PSE port is trying to detect the connection of PD.
Delivering-Power - Specifies PSE port is delivering power to PD.
Test - Specifies PSE port IS under test.
Fault - Specifies PSE port operation fault defined in IEEE 802.3af and 802.3at.
Other Fault - Specifies PSE port operation fault other than those defined in
IEEE 802.3af and 802.3at.
Fault Status
Displays the fault indication of PSE port.
None - Specifies PSE port detects no error condition.
Short-Circuit - Specifies PSE port detects short circuit in PD loop.
Over-Load - Specifies PSE port detects lover-load in PD loop.
Power-Denied - Specifies PSE port denies PD power class request.
Startup-Failure - Specifies PSE port operation fault defined in IEEE 802.3af and
802.3at.
Other-Fault - Specifies PSE port fault other than those defined in IEEE 802.3af
and 802.3at.
Submit
Click
Submit
to update the screen. To save the values across a power cycle per-
form a system save.
Refresh
Click
Refresh
to update the screen.