Table 1-1.
EKI-9316P / EKI-9312P Specifications (Continued)
Specifications
Description
Certifications
EMC
CE, FCC Class A
UL60950 C1D2
EN61000-6-4; EN61000-6-2; EN61000-4-2 (ESD)
Level 4
EN61000-4-3 (RS) Level 4; EN61000-4-4 (EFT)
Level 4
EN61000-4-5 (Surge) Level 4; EN61000-4-6 (CS)
Level 3
EN61000-4-8 (Magnetic Field) Level 4
EN50121-4
Shock
IEC60068-2-27
Free fall
IEC60068-2-32
Vibration
IEC60068-2-6
1.4.2 EKI-9316 / EKI-9312
Table 1-2.
EKI-9316 / EKI-9312 Specifications
Specifications
Description
Interface
I/O Port
8 x 10/100/1000Base-T/TX RJ-45
12 x 10/100/1000Base-T/TX RJ-45
4 x 100/1000Base-FX/X SFP (P1~P4)
Console port
RJ-45
F/W backup port
USB (support Transcend and ATP USB)
Power Connector
6-pin screw Terminal Block (including relay)
Physical
Enclosure
Aluminum Shell
Protection Class
IP30
Installation
DIN-Rail
Dimensions
86 x 165 x 125 (mm)
(W x H x D)
3.39 x 6.5 x 4.92 (inch)
LED Display
System LED
PWR1, PWR2, SYS, CFG, Alarm and R.M.
Port LED
Link / Speed / Activity
Environment
Operating Tem-
-40°C ~ 75°C (-40°F ~ 167°F)
perature
Storage Tempera-
-40°C ~ 85°C (-40°F ~ 185°F)
ture
Ambient Relative
10 ~ 95% (non-condensing)
Humidity
7