Leave Timer (centi-
Enter a value to specify the time to wait after receiving an unregister request for a
secs)
VLAN or multicast group before deleting the associated entry, in centiseconds. This
allows time for another station to assert registration for the same attribute in order
to maintain uninterrupted service. Enter a number between 20 and 600 (0.2 to 6.0
seconds). The factory default is 60 centiseconds (0.6 seconds). An instance of this
timer exists for each GARP participant for each port.
Join Timer (centi-
Enter a value to specify the time between the transmission of GARP PDUs regis-
secs)
tering (or re-registering) membership for a VLAN or multicast group in centisec-
onds. Enter a number between 10 and 100 (0.1 to 1.0 seconds). The factory
default is 20 centiseconds (0.2 seconds). An instance of this timer exists for each
GARP participant for each port.
Leave All Timer (cen-
Enter a value to specify the Leave All Time controls how frequently LeaveAll PDUs
tisecs)
are generated. A LeaveAll PDU indicates that all registrations will shortly be dereg-
istered. Participants will need to rejoin in order to maintain registration. The Leave
All Period Timer is set to a random value in the range of LeaveAllTime to 1.5*Lea-
veAllTime. The timer is specified in centiseconds. Enter a number between 200
and 6000 (2 to 60 seconds). The factory default is 1000 centiseconds (10 sec-
onds). An instance of this timer exists for each GARP participant for each port.
Submit
Click
Submit
to update the switch with the values on the screen. If you want the
switch to retain the new values across a power cycle you must perform a save.