BZ001M056A
ADT
‐
DK300A/400A
Engraving
Machine
99
acceleration/deceleration,
and
this
parameter
is
valid
in
preprocessing
mode.
084
HOME
Check
for
alarm
085
HOME
Check
Enable
Range
:
0~1
Unit
:
None
Authority
:
Operation
admin
or
higher
Default
:
0,
1
Effective
time
:
Instant
Note
:
Used
to
set
whether
prompt
user
to
reset
under
certain
conditions,
ensuring
that
the
user
has
performed
the
operation;
If
the
value
is
set
to
0,
it
won’t
check,
and
will
run
directly.
087
Default
process
plane
Range
:
G17,18,19
Unit
:
None
Authority
:
Operation
admin
or
higher
Default
:
G18
(L
series)/G17
(M
series)
Effective
time
:
Instant
Note
:
Set
the
default
processing
plane
to
XY
or
XZ;
modify
the
default
plane,
so
that
it
isn’t
need
to
specify
the
modal
plane
value
while
programming,
and
write
plane
related
instructions
directly
in
stead;
089
IP
address
090
Subnet
mask
091
Default
gateway
Range
:
0~255
Unit
:
None
Authority
:
Operation
admin
or
higher
Default
:
192.168.0.123
255.255.255.0
192.168.0.1
Effective
time
:
Restart
Note
:
Used
to
configure
Ethernet
parameters,
which
shall
comply
with
the
actual
network
settings,
or
else
it
can’t
be
accessed
normally.
After
configured
successfully,
the
user
can
perform
the
ping
command
Содержание ADT-DK300A
Страница 66: ...BZ001M056A ADT DK300A 400A Engraving Machine 57 ...
Страница 160: ...BZ001M056A ADT DK300A 400A Engraving Machine 151 11 2 3 Digital output interface XS6 ...
Страница 166: ...BZ001M056A ADT DK300A 400A Engraving Machine 157 11 3 2 Power connection diagram ...
Страница 167: ...BZ001M056A ADT DK300A 400A Engraving Machine 158 11 3 3 Servo drive connection diagram ...
Страница 168: ...BZ001M056A ADT DK300A 400A Engraving Machine 159 11 3 4 Step connection diagram ...