BZ001M056A
ADT
‐
DK300A/400A
Engraving
Machine
106
Authority
:
Operation
admin
or
higher
Default
:
0
Effective
time
:
Instant
Note
:
Purpose
and
function
to
be
specified
10.3.
Axis
parameter
configuration
(P2.)
001
X_ServoAlarmIn
ELevel
002
Y_ServoAlarmIn
ELevel
003
Z_ServoAlarmIn
ELevel
004
A_ServoAlarmIn
ELevel
005
X_ServoResetOut
ELeve
006
Y_ServoResetOut
ELeve
007
Z_ServoResetOut
ELeve
008
A_ServoResetOut
ELeve
Range
:
0~1
Unit
:
LOGIC
VOLTAGE
LEVEL
Authority
:
Super
Admin
Default
:
1,
1
Effective
time
:
Instant
Note
:
Adapt
to
the
interface
parameters
of
selected
servo
drive;
please
refer
to
interface
voltage
level
description
of
servo
for
specific
parameter
settings.
Servo
alarm
effective
level
can
be
set
to
0
for
stepper
motor,
or
else
servo
alarm
will
be
generated
because
the
port
level
read
by
the
system
is
1.
Reset
effective
level
refers
that
the
system
will
output
alarm
reset
signal
from
pulse
port
if
the
user
presses
the
Reset
key
when
servo
alarm
occurs.
009
X_ECZ
Home
Enable
010
X_ECZ
Home
ELevel
011
Y_ECZ
Home
Enable
012
Y_ECZ
Home
ELevel
013
Z_ECZ
Home
Enable
014
Z_ECZ
Home
ELevel
Содержание ADT-DK300A
Страница 66: ...BZ001M056A ADT DK300A 400A Engraving Machine 57 ...
Страница 160: ...BZ001M056A ADT DK300A 400A Engraving Machine 151 11 2 3 Digital output interface XS6 ...
Страница 166: ...BZ001M056A ADT DK300A 400A Engraving Machine 157 11 3 2 Power connection diagram ...
Страница 167: ...BZ001M056A ADT DK300A 400A Engraving Machine 158 11 3 3 Servo drive connection diagram ...
Страница 168: ...BZ001M056A ADT DK300A 400A Engraving Machine 159 11 3 4 Step connection diagram ...