FOCUS 200 PLUS Installation and Setup Guide
19-12
Option
Function
Bell Delay
This is used to delay local annunciation of alarms for a BA group during
Nite Set for up to 20 minutes. It applies to both the operating panel sounder
and the local bell. Messages to the CCC, however, are sent without the
delay. The delay is automatically cancelled if a telco failure occurs.
Bell Cutoff
This determines the length of time the local BA bell and operating panels
will annunciate. The cutoff time can be any number of whole minutes from
0 to 255.
UL
•
In UL installations, the BA bell ring time should be at least 15 minutes.
•
The Bell Delay may not be used in UL Burglary alarm systems.
Option
Function
SANS
This represents the type of CCC monitoring that will be provided for the BA
group. Refer to the System Communication section for an explanation of the
types of services that are available.
Interlock On
This prevents the protection for a BA group being from being turned on
unless a specific combination of BA groups has been turned on. As an
example, it can be used to ensure that the vault protection has been turned
on before the bank perimeter protection can be turned on.
Schedule Lock
This prevents the BA group from being turned off outside the scheduled
open time period. Use this option only on safes, vaults, or other high
security areas where the operating panel is located outside the protected
area.
ATM Off
This is primarily an Automatic Teller Machine (ATM) option. It prevents
the protection for a BA group from being turned off unless the protection is
on for specified BA group(s). Typically, it is used to prevent more than one
ATM from being turned off at any given time.
Recycling Exit Delay
UL
Recycling Exit Delay may not be used on UL Burglary alarm systems.
A Recycling Exit Delay has been incorporated into FOCUS 200 PLUS to minimize the possibility of
creating a false alarm when someone turns the protection On, exits, and then returns to get something
that was left behind. The Recycling Exit Delay operates as follows:
The BA group is turned on to start the programmed exit delay, and a 10-minute time window is
started. During this time window, an alarm from a movable instant or delayed point from any group in
exit delay automatically recycles all groups in exit delay back to their full exit delay time. This means
that the full exit delay is usually in effect when the person exits, and the delay is recycled to start anew
when that person returns and opens the door again. The exit delay also recycles for each movable point
that is tripped by the person returning.
The recycling of the exit delay can occur any number of times during the 10-minute time window. At
the end of the 10-minute time window, the exit delay will unconditionally start one last time. If the
door is not closed by the end of this last exit delay, a trouble-closing signal will be sent to the CCC.
If the "audible on exit" option was selected for the BA group being turned on, the operating panel (and
Remote Sonalert output point) beeps once per second to annunciate the exit delay period. This exit
delay annunciation is interrupted during the time that a movable delayed point in that BA group is in
alarm, and the sounder goes on steady during the time that a movable instant point of that BA group is
in alarm. In each case, the annunciation resumes when the point restores.
Содержание Commercial Fire & Burglary Alarm System FOCUS 200 PLUS
Страница 2: ......
Страница 22: ...FOCUS 200 PLUS Installation and Setup Guide 3 6...
Страница 28: ...FOCUS 200 PLUS Installation and Setup Guide 4 6...
Страница 64: ...FOCUS 200 PLUS Installation and Setup Guide 6 8...
Страница 76: ...FOCUS 200 PLUS Installation and Setup Guide 7 12...
Страница 110: ...FOCUS 200 PLUS Installation and Setup Guide 10 24...
Страница 166: ...FOCUS 200 PLUS Installation and Setup Guide 16 4...
Страница 196: ...FOCUS 200 PLUS Installation and Setup Guide 21 4...
Страница 204: ...FOCUS 200 PLUS Installation and Setup Guide 22 8...
Страница 210: ...Index Index 6...
Страница 214: ...A 4...
Страница 216: ...9 3l K3471V2 1 00 ADT Security Services Inc One Town Center Road Boca Raton FL 33486 Copyright 1999...