![ADT Commercial Fire & Burglary Alarm System FOCUS 200 PLUS Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/adt/commercial-fire-and-burglary-alarm-system-focus-200-plus/commercial-fire-and-burglary-alarm-system-focus-200-plus_installation-and-setup-manual_2854006082.webp)
FOCUS 200 PLUS Installation and Setup Guide
9-2
Entry
Number
Description
Function
16 (TFC)
Telco Fault
Output turns on if a telco fault condition occurs (low voltage or loss of
interrogation on AC telco line). The output turns off when the telco
line becomes normal.
17 (SCC)
BA Schedule
Output turns on at the start of the scheduled open period for a
designated BA group, and turns off when the close schedule starts.
18 (LTC)
BA Lights
Output turns on when the protection of a pre-selected BA group is
turned off, or the entry/exit delay period is activated. The output
turns off when the protection of a BA group is turned on.
Note: If the Recycle Exit Delay is enabled, the output turns on
whenever any key is pressed on the operating panel.
19 (FXC)
BA Fixed
Output turns on when any BA Fixed or Fixed Local type point goes
into alarm or, during Day Set, an Instant Daytime Annunciation type
point goes into alarm. Output turns off when a valid ID code is
entered at any operating panel.
20 (OFC)
BA Off
Output turns on when the protection of a selected BA group is turned
off, and turns off when the protection is turned on.
21 (FAC)
Fire
Output turns on and latches when any fire type point in the system
goes into alarm. The output turns off when the alarm condition has
been cleared and the fire alarm is reset.
Fire Point (Silence) Option: This output point turns on and
latches when fire alarm input goes into alarm. If the Silence option is
selected, the output will unlatch by entering a valid ID code (or Fire
Marshall Code 222222) at any operating panel.
22 (SPC)
Supervisory
Output turns on if any supervisory type point goes into alarm, and
turns off when the point restores.
23 (HUC)
Holdup
Output turns on if:
•
A holdup type point goes into alarm. The output turns off when
the holdup device is manually reset.
•
The ambush feature is activated. The output turns off when the
operating panel times out.
•
A duress signal is initiated at any operating panel. The output
turns off when the operating panel times out.
24 (HSC)
Holdup
Suspicion
Output turns on when either a Holdup type point or a Holdup Special
type point, in which the Suspicion option has been selected, goes into
alarm. The output, which can be used to control a holdup and
suspicion camera, turns off when the point restores.
25 (RSC)
BA Remote
Sonalert
Output turns on to operate Sonalert(s) during any of the following:
•
Output follows the steady, keypad-audible pattern during the
pre-alarm entry delay of the selected BA group, and operates the
2-seconds-On, 2-seconds-Off pattern during the exit delay.
•
During the holdup test (regardless of the BA group involved),
output operates the 2-seconds-On, 2-seconds-Off pattern while
the point being tested is normal, and turns on steady when the
point is in alarm. When the point is restored to normal, the
output reverts to the 2-seconds-On, 2-seconds-Off operation until
the test is ended.
•
Output turns on for 2 seconds, once each minute, during the
programmed closing reminder time of the selected BA group, and
turns on steady during the close warning period.
Содержание Commercial Fire & Burglary Alarm System FOCUS 200 PLUS
Страница 2: ......
Страница 22: ...FOCUS 200 PLUS Installation and Setup Guide 3 6...
Страница 28: ...FOCUS 200 PLUS Installation and Setup Guide 4 6...
Страница 64: ...FOCUS 200 PLUS Installation and Setup Guide 6 8...
Страница 76: ...FOCUS 200 PLUS Installation and Setup Guide 7 12...
Страница 110: ...FOCUS 200 PLUS Installation and Setup Guide 10 24...
Страница 166: ...FOCUS 200 PLUS Installation and Setup Guide 16 4...
Страница 196: ...FOCUS 200 PLUS Installation and Setup Guide 21 4...
Страница 204: ...FOCUS 200 PLUS Installation and Setup Guide 22 8...
Страница 210: ...Index Index 6...
Страница 214: ...A 4...
Страница 216: ...9 3l K3471V2 1 00 ADT Security Services Inc One Town Center Road Boca Raton FL 33486 Copyright 1999...