Section 15 – Scheduling
15-5
Scheduling Options
The options associated with scheduling are outlined in the following table:
Option
Function
Auto On/Off may be convenient to use for an area where people come and go as
they please, and no one is responsible for turning the protection on or off.
The burglar alarm protection associated with each schedule can be:
•
Turned on and off manually.
•
Turned on and off automatically.
•
Turned on automatically and
turned off manually.
•
Turned on manually and turned
off automatically.
Auto On/Off
Example: If auto-on/auto-off is selected for a given BA group, it automatically
goes to Nite Set at the scheduled closing time, and automatically goes to Day Set
at the scheduled opening time without anyone having to go to an operating panel.
The closing time reminder and warning sounder operate as a reminder to exit
However, there is no warning sound during the entry delay because the opening
is being done automatically.
Notes:
•
The system performs the auto-on at the end of the warning time.
•
Auto-On/Off may not be used in UL burglary alarm systems.
•
The auto-on will not occur if there are faults on any sensors in the group.
Early Open/
Late Close
This establishes the earliest opening and latest closing times that can be used
each day for the permanent and temporary schedules for a given BA group.
Schedule
Lockout
This is intended for use with areas involving safes, vaults, or other high-security
areas where the operating panel is located outside of the protected area. It is
used to prevent a BA group from being turned Off when the present time is
outside the scheduled open period.
Early Open/Late Close Options
The following table describes the options for establishing the limits for the earliest opening and latest
closing time for a BA group. The limits apply to both the permanent and temporary schedules:
Option Time
Function
Earliest Open Time
00 to 23
This sets the time limit, in 1-hour increments, from 12
midnight (00) to 11 PM (23). A schedule can be programmed
at or after the earliest open time.
For example, selecting 5 AM as the earliest open time means
a schedule can be programmed at or after 5 AM by a user.
24 (Lock) This locks the opening time for the permanent schedule so
that no temporary schedule changes can be made (from the
operating panel).
Latest Close Time
00 (Lock) This locks the permanent schedule closing times so that no
temporary schedule closing times can be programmed from
the operating panel.
01 to 23
This choice sets the time limit, in 1-hour increments, from
1 AM (01) to 11 PM (23), for the latest permissible closing
time. A permanent or temporary closing schedule cannot be
extended beyond the latest closing time.
24
Allows any close time up to 11:44 PM, but the closing time
cannot be deleted.
25
Deletes all restrictions on closing schedules. Allows for the
spanning of midnight and deleting schedules.
Содержание Commercial Fire & Burglary Alarm System FOCUS 200 PLUS
Страница 2: ......
Страница 22: ...FOCUS 200 PLUS Installation and Setup Guide 3 6...
Страница 28: ...FOCUS 200 PLUS Installation and Setup Guide 4 6...
Страница 64: ...FOCUS 200 PLUS Installation and Setup Guide 6 8...
Страница 76: ...FOCUS 200 PLUS Installation and Setup Guide 7 12...
Страница 110: ...FOCUS 200 PLUS Installation and Setup Guide 10 24...
Страница 166: ...FOCUS 200 PLUS Installation and Setup Guide 16 4...
Страница 196: ...FOCUS 200 PLUS Installation and Setup Guide 21 4...
Страница 204: ...FOCUS 200 PLUS Installation and Setup Guide 22 8...
Страница 210: ...Index Index 6...
Страница 214: ...A 4...
Страница 216: ...9 3l K3471V2 1 00 ADT Security Services Inc One Town Center Road Boca Raton FL 33486 Copyright 1999...