For the electrofusion cable replacement, proceed with the following steps:
1.
Using a 24mm open-end spanner, hold the gray reducer (Figure 12a).
2.
Using a second 24mm open-end spanner, unscrew the cable gland (Figure 12b).
Figure 12a
Figure 12b:
Figure 12c
Figure 12d
3.
With the cable gland totally unscrewed, pull the cable out to get access to the
connecting point (Figure 12c).
4.
Unfasten the connection between the internal cable and the electrofusion cable
holding the nut with an 8mm open-end spanner and loosen the screw with a 3mm
Allen key (Figure 12d). Attention, do not lose the safety washer !.
5.
Replace the electrofusion cable and assemble on the opposite sequence.
5.2.3 Assembly of the fan kit (if it is not already installed):
Even though the BEAT-HF electrofusion unit is of high-perfor
mance, for models on it is not already installed a cooler fan kit
can be mounted externally without the need of opening the unit,
this to increase its performance even more.
The unit comes provided with a pre-installed feed connection for
the cooler fan kit.
To assemble it, connect the fan to the pre-installed electric
terminal in the unit and slide the four nuts screwed to the cooler
fan bracket bolts through the lateral heat sink mounting rails.
Once in position, tighten the four nuts.
Figure 13