![Acuster BEAT HF Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/acuster/beat-hf/beat-hf_user-manual_2845321055.webp)
USER MANUAL
BEAT HF
Edition: January 2016
Revision: No. 4
TROUBLESHOOTING -
55
If the electrofusion current is too low, the display will show:
nnnn
hh:mm
40.0 V 0075s 2.25
S
0065s
Current too low
The fitting barcode parameters entered are still on the
upper line.
The time counter will display the remaining cycle time
at the moment of stopping.
Press <START> to continue. The next screen will show Fusion data to restart the
electrofusion process from the very beginning.
This message appears in the following cases:
1. Fitting not connected.
2. Disconnection of the electrofusion terminals.
3. Cut in the filament of the fitting resistance.
4. If the electrofusion current is lower than 2 A.
4.2.5 Elecrofusion output voltage:
If there is a deviation higher than ± 0,5 V in the output voltage during the electrofusion
of the fitting, the cycle will stop and the display will show:
nnnn
hh:mm
40.0 V 0075s 2.25
S
0065s
Voltage failure
The fitting barcode parameters entered are still on the
upper line.
The time counter will display the remaining cycle time
at the moment of stopping.
Press <START> to continue. The next screen will show Fusion data to restart the
electrofusion process from the very beginning.
This message may also appear due to incorrect fitting application (fitting voltage outside
range).
4.2.6 Communication error:
In case of an internal communication error between the power board and the CPU board
is detected, when the electrofusion cycle is started the following message will appear:
nnnn
hh:mm
40.0 V 0075s 2.25
S
xxxxs
Communication error
The fitting barcode parameters entered are still on the
upper line.
Where xxxxs corresponds to the remaining cycle time
at the moment of stopping.
It is advised to send the unit to the After-Sales Service for its check and repair.