![Acuster BEAT HF Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/acuster/beat-hf/beat-hf_user-manual_2845321030.webp)
USER MANUAL
BEAT HF
Edition: January 2016
- MODE OF USE
Revision: No. 4
30
MODELS BEAT HF-2 & BEAT HF-Tr
3.4.4 Entering the electrofusion data in the unit:
Initial screen:
Note for model BEAT HF-Tr: if the input of data related to Operator, Job, Additional data
and Traceability is disabled, or if enabled, once validated, the following screen will appear:
nnnn
hh:mm
Fusion data
vvv V ff Hz tt
/
C
Read barcode
Read barcode is displayed by default. Press either the
or arrow to select the Manual fusion or Edit
barcode screen, as required.
Select the Manual fusion option when the electrofusion parameters (voltage and time)
need to be introduced manually and select Edit barcode when the fitting manufacturer’s
data needs to be used and an optic pen or scanner is not available.
â
C
Selecting the Read barcode option:
nnnn
hh:mm
Fusion data
vvv V ff Hz tt
/
C
Read barcode
Where the following information will appear:
nnnn:
Fusion number
hh:mm:
Time
vvv V ff Hz:
Input voltage and frequency
tt
/
C:
Room temperature
With the optic pen or scanner connected to the serial connector, read the barcode of the
fitting.
WARNING !
Make sure you always read the barcode corresponding to the fitting to be
electrofused. Should you not record the fitting’s data, this could cause
errors in the electrofusion process that would have repercussions on the
quality and reliability of the joint.
nnnn
hh:mm
Coupler
AG d63
40.0 V 75s 2.25
S
Confirm
Where the following information appears:
Coupler:
Type of fitting connected
AG d63:
Make and diameter of fitting
40.0V 75s 2.25
S
:
Electrofusion parameters
If the barcode or reading were erroneous.
nnnn
hh:mm
Fusion data
vvv V ff Hz tt
/
C
Wrong data
If a barcode has been entered incorrectly, the unit will
emit two acoustic signals and a Wrong data will
appear on the screen.
Read the barcode again.