![Acuster BEAT HF Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/acuster/beat-hf/beat-hf_user-manual_2845321045.webp)
USER MANUAL
BEAT HF
Edition: January 2016
Revision: No. 4
MODE OF USE -
45
C
PRINT:
Validate the following Print option menu to print the fusion data to a serial printer.
Last fusion
Today’s fusions
All fusions
Date range
–
•
Use the and keys to move to the selected option
and the <START> key to validate.
Connect the unit to a serial printer using the ODS
transmission cable.
Printer setup (for the first time):
Before using the serial printer on the electrofusion unit, be sure that the printer’s DIP-
Switches are correctly selected. The setup for a printer Citizen, model CT-S280, is the
following:
1
2
3
4
5
6
7
8
ON
x
x
x
x
OFF
x
x
x
x
The generic setup for an appropriate data print-out on other printer makes and models
is:
C
XON/XOFF
C
8 bits
C
Parity: NONE
C
19200 Bauds
C
1 Stop bit
Printing:
Validate this option to print the options: Last Fusion / Today’s fusions / All fusions
/ Date range.
Use the and keys to move to the desired option and the <START> key to validate.
Press the <START> key to print the fusion data.
If you select the last option of Date range, the display will show the following screen:
Print range
DD / MM / YY
dd / mm / yy
Confirm
DD/MM/YY corresponds to the earliest fusion record
(the first by default) and dd/mm/yy to the latest.
Press the and arrows to move the cursor to a different field and the and arrows
to modify the values.
Press the <START> key to print.