![Acuster BEAT HF Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/acuster/beat-hf/beat-hf_user-manual_2845321036.webp)
USER MANUAL
BEAT HF
Edition: January 2016
- MODE OF USE
Revision: No. 4
36
3.5
ACCESS TO OTHER MENUS
3.5.1 Available options:
You can access other menus by pressing the <START> key and then starting up the unit
at the main power supply.
For models BEAT HF-MV and BEAT HF-2, there are a total of 2 menu options: INFORMA-
TION / SETUP, whereas on model BEAT HF-Tr there are three: INFORMATION / FUSIONS
/ SETUP, accessed by sequentially pressing the key.
Information
Fusions (Tr only)
Setup
–
•
Use the and keys to move to select option and
validate with <START> key.
3.5.2 Information option:
Validating the Information menu’s first option:
dd/mm/yy
hh:mm
V v.vv UK P. v.vv
S.N. xxxx/yyyy TT
/
C
Lifetime 000000
0000-000-0-0-0
½
This information is
shown on two screen-
s. Press the arrow
to go to screen 2/2.
dd/mm/yy
hh:mm
Last Rev.
dd/mm/yy
Limit
dd/mm/yy
Warning
dd/mm/yy
Lock
OFF/ON
2/2
dd/mm/yy hh:mm :
Date and time.
V v.vv UK P. v.vv
:
V software version, UK are the abbreviations of the set
language and P software version of the power board.
S.N.
TT
/
C
:
S.N. corresponds to the unit’s serial number (xxxx) and the
CPU’s serial number (yyyy); TT
/
C corresponds to the room
temperature.
Lifetime
:
This field indicates the time in minutes during which the unit
has been fusing (real time of use).
0000-000-0-0-0
:
These five fields indicate the status of the setup options in this
order: Operator, Job, Additional data, Traceability and Manual
electrofusion.
All zeros indicate that all options are inactive (OFF).
1248-124-1-1-1
:
This setup indicates that all options have been activated (ON).
The Operator and Job options can be partly activated.
Last Rev.
:
dd/mm/yy corresponds to the date of the last service carried
out on the unit.
Limit
:
dd/mm/yy corresponds to the date set for the unit’s next
service.
Warning
:
dd/mm/yy corresponds to the date at which the warning
message for the next service will begin to appear.
Lock
:
ON indicates that the unit will be blocked when the deadline
expires; when OFF the unit will remain operative despite the
deadline having expired.
Press either <STOP> or <START> to exit this option.