5.2
MAINTENANCE OF THE FUSION CONTROL BOX
5.2.1 Fusion control box:
Besides the exterior cleaning of the casing, there is no specific maintenance for the
electronic control unit. Tune-ups and adjustments should be performed by qualified
personnel, or by an STPAcuster group authorized distributor.
5.2.2 Replacement of electric cables:
The electrofusion unit BEAT-HF has been designed in a way that small maintenance jobs
such as the replacement of electric cables due to daily use (generally bad use) can be
carried out by the unit’s owner or the company’s maintenance department.
CAUTION !
Perform this operation with the unit disconnected. There is a potential
danger of electrical shock.
Mains cable (model 2008 only):
The power cable is connected in the unit through a circular multi-contact connector. In the
event of failure or damage, it can easily be replaced by a new one supplied by an
STPAcuster group authorized distributor.
Figure 11a: Mains cable (plugged)
Figure 11b: Mains cable (unplugged)
Electrofusion cables:
The unit’s electrofusion cables are connected to their respective internal cables by means
of an external connection which allows the cables to be replaced without opening the rear
cover. In the event of failure of damage, they can easily be replaced by new ones supplied
by an STPAcuster group authorized distributor.