Serinus 60 User Manual 3.0
Page 40
Readings (1)
Displays the concentration being measured in real-time. The display can be configured to show just
the instantaneous data or the instantaneous and average data (refer to Section 3.3.2
Home Screen
).
Error/Status Line (2)
The error/status line provides users with information on any problems the instrument may have. It
displays the highest priority error or status condition contained in the
Status Menu
(refer to Section
Instrument Activity (3)
This line shows what function the instrument is currently performing. Generally, it will show three
groups of actions: Warm-up, Measurement or Calibration.
Selection Buttons (4)
These buttons are used on the home screen to enter one of two menus. The
Quick Menu
(refer to
Section 3.4.1) contains all information and features necessary for scheduled maintenance. The
Main
Menu
(refer to Section 3.4.2) contains all information and fields available to users and is generally
only used during initial set-up and diagnostics.
Time and Date (5)
The time and date are displayed in between the menu buttons at the bottom of the screen.
Concentration Units (6)
The instrument units are displayed in the bottom right hand corner of the display.
USB Detection (7)
A USB symbol will be displayed in the bottom right corner when the USB memory stick is plugged in
(the USB socket is behind the front panel). If the USB symbol is not shown, the USB memory stick
should be inserted. Underneath the USB symbol arrows may be displayed which indicates data
transfer. The USB memory stick must not be removed whilst the arrows are visible.
Note:
To safely remove the USB memory stick, navigate to the
Quick Menu
and use the
Safely
Remove USB Stick
function (refer to Section 3.4.1).
3.4
Menus & Screens
The menu system is divided into two sections, the
Quick Menu
and the
Main Menu
selectable from
the
Home Screen
. The
Quick Menu
contains all information and operations necessary during
scheduled maintenance visits. The
Main Menu
contains all fields that are accessible to users. It
provides information on component failures and measurement parameters as well as editable fields
and test procedures.
In general, editable parameters are displayed in bold font. Non-editable information is displayed in a
thin font. Some parameters may become editable based on the state of the instrument.
Содержание Met One Instruments GAS-1060
Страница 10: ...Serinus 60 User Manual 3 0 Page 10 This page is intentionally blank...
Страница 18: ...Serinus 60 User Manual 3 0 Page 18 This page is intentionally blank...
Страница 35: ...Installation Page 35 Figure 7 Switching the Battery On Off...
Страница 36: ...Serinus 60 User Manual 3 0 Page 36 This page is intentionally blank...
Страница 102: ...Serinus 60 User Manual 3 0 Page 102 This page is intentionally blank...
Страница 122: ...Serinus 60 User Manual 3 0 Page 122 7 6 USB Memory Stick Failure Figure 64 USB Memory Stick Failure...
Страница 134: ...Serinus 60 User Manual 3 0 Page 134 9 5 Plumbing Schematic PN D020060...
Страница 135: ...Parts List Page 135 9 6 Block Wiring Schematic PN D020111...
Страница 136: ...Serinus 60 User Manual 3 0 Page 136 9 7 Measurement Cell Side Section PN H015000...
Страница 137: ...Parts List Page 137...
Страница 138: ...Serinus 60 User Manual 3 0 Page 138 9 8 Calibration Valve Manifold Assembly Exploded View PN H010013 01...
Страница 139: ...Parts List Page 139 9 9 Valve Assembly Exploded View PN H010042...
Страница 140: ...Serinus 60 User Manual 3 0 Page 140 9 10 High Pressure Valve Exploded View PN H050043...