Autophasing modes
Several autophasing modes are available (see parameter
The turning mode (
) is recommended especially with case 1 (see the list
above) as it is the most robust and accurate method. In turning mode, the motor
shaft is turned back and forward (±360/polepairs)° in order to determine the rotor
position. In case 3 (open-loop control), the shaft is turned only in one direction
and the angle is smaller.
Another turning mode,
, can be used if there is difficulty using
the normal turning mode, for example, because of significant friction. With this
mode, the rotor is turned slowly until a zero pulse is detected from the encoder.
When the zero pulse is detected for the first time, its position is stored into
parameter
, which can be edited for fine-tuning. Note that it is not mandatory
to use this mode with a zero pulse encoder. In open-loop control, the two turning
modes are identical.
The standstill modes (
) can be used if the motor cannot be
turned (for example, when the load is connected). As the characteristics of motors
and loads differ, testing must be done to find out the most suitable standstill
mode.
The drive is capable of determining the rotor position when started into a running
motor in open-loop or closed-loop control. In this situation, the setting of
has no effect.
The autophasing routine can fail and therefore it is recommended to perform the
routine several times and check the value of parameter
An autophasing fault (
) can occur with a running motor if the estimated angle
of the motor differs too much from the measured angle. This could be caused by,
for example, the following:
•
The encoder is slipping on the motor shaft
•
An incorrect value has been entered into
•
The motor is already turning before the autophasing routine is started
•
mode is selected in
but the motor shaft is locked
•
mode is selected in
but no zero pulse is detected
within a revolution of the motor
•
The wrong motor type is selected in
•
Motor ID run has failed.
Settings and diagnostics
Parameters:
6.21 Drive status word 3 (page 157)
21.13 Autophasing mode (page 258)
,
98.15 Position offset user (page 535)
and
99.13 ID run requested (page 539)
.
Program features 91
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...