
Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
0.00 mH / real32
Defines the direct axis (synchronous) inductance.
Note: This parameter is valid only for permanent
magnet motors.
Ld user SI
98.13
10 = 1 mH / 100 = 1
mH
Direct axis inductance.
0.00 ... 100000.00
mH
0.00 mH / real32
Defines the quadrature axis (synchronous) inductance.
Note: This parameter is valid only for permanent
magnet motors.
Lq user SI
98.14
10 = 1 mH / 100 = 1
mH
Quadrature axis inductance.
0.00 ... 100000.00
mH
0.0 deg / real32
Defines an angle offset between the zero position of
the synchronous motor and the zero position of the
position sensor.
This value is initially set by the autophasing routine
when an absolute encoder or an incremental encoder
with Z-pulse is used. The value can be fine-tuned by
setting
to
or
Motor parameters & position offset
Note: The value is in electrical degrees. The electrical
angle equals the mechanical angle multiplied by the
number of motor pole pairs.
Note: This parameter is valid only for permanent
magnet motors.
Position offset user
98.15
1 = 1 deg / 1 = 1 deg
Angle offset.
0.0 ... 360.0 deg
Parameters 535
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...