Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
- / real32
With interface module 1, defines when zero pulses are
emulated in relation to zero position received from the
encoder.
For example, with a value of 0.50000, a zero pulse is
emulated whenever the encoder position passes 0.5
revolutions. With a value of 0.00000, a zero pulse is
emulated whenever the encoder position passes zero
position.
Module 1 emulated
Z-pulse offset
91.33
32767 = 1 rev /
100000 = 1 rev
Position of emulated zero pulses.
0.00000 ... 1.00000
rev
500 us / uint16
Selects a low-pass filter time for all of the digital inputs
of encoder interface module 1.
Module 1 latch
trigger filter time
91.35
0
125 microseconds.
125 us
1
250 microseconds.
250 us
2
500 microseconds.
500 us
3
1 millisecond.
1 ms
4
2 milliseconds. (Requires logic version VIE02200 /
VIE12400 / VIE22200 / VIE32400 or later.)
2 ms
5
4 milliseconds. (Requires logic version VIE02200 /
VIE12400 / VIE22200 / VIE32400 or later.)
4 ms
Not selected / uint16
Selects the encoder input on interface module 2 whose
signal is echoed by or emulated to the TTL output.
See also section
Module 2 TTL output
source
91.41
0
TTL output not in use.
Not selected
1
Input 1 is echoed by or emulated to the TTL output.
Module input 1
2
Input 2 is echoed by or emulated to the TTL output.
Module input 2
- / uint16
Defines the number of TTL pulses per revolution for
encoder emulation output of interface module 2.
Module 2 emulation
pulses/rev
91.42
1 = 1 / 1 = 1
Number of TTL pulses for emulation.
0...65535
- / real32
With interface module 2, defines when zero pulses are
emulated in relation to zero position received from the
encoder.
For example, with a value of 0.50000, a zero pulse is
emulated whenever the encoder position passes 0.5
revolutions. With a value of 0.00000, a zero pulse is
emulated whenever the encoder position passes zero
position.
Module 2 emulated
Z-pulse offset
91.43
32767 = 1 rev /
100000 = 1 rev
Position of emulated zero pulses.
0.00000 ... 1.00000
rev
500 us / uint16
Selects a low-pass filter time for all of the digital inputs
of encoder interface module 2.
For the selections, see
91.35 Module 1 latch trigger filter
Module 2 latch
trigger filter time
91.45
492 Parameters
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...