Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
0 Hz / real32
Defines the minimum for the frequency actually arriving
at frequency input 1 (DIO1 when it is used as a
frequency input).
The incoming frequency signal (
) is scaled into an internal signal (
) by parameters
as follows:
11.39
f
in
(
11.38 )
11.42
11.43
11.45
11.44
Freq in 1 min
11.42
1 = 1 Hz / 1 = 1 Hz
Minimum frequency of frequency input 1 (DIO1).
0...16000 Hz
16000 Hz / real32
Defines the maximum for the frequency actually arriving
at frequency input 1 (DIO1 when it is used as a
frequency input).
See parameter
Freq in 1 max
11.43
1 = 1 Hz / 1 = 1 Hz
Maximum frequency for frequency input 1 (DIO1).
0...16000 Hz
0.000 / real32
Defines the value that is required to correspond
internally to the minimum input frequency defined by
parameter
. See diagram at
parameter
.
Freq in 1 at scaled
min
11.44
1 = 1 / 1000 = 1
Value corresponding to minimum of frequency input
1.
-32768.000 ...
32767.000
1500.000; 1800.000
(95.20 b0) / real32
Defines the value that is required to correspond
internally to the maximum input frequency defined by
parameter
. See diagram at
parameter
.
Freq in 1 at scaled
max
11.45
1 = 1 / 1000 = 1
Value corresponding to maximum of frequency input
1.
-32768.000 ...
32767.000
- / real32
Displays the value of frequency output 1 after scaling.
See parameter
.
This parameter is read-only.
Freq out 1 actual
value
11.54
1 = 1 Hz / 1 = 1 Hz
Value of frequency output 1.
0...16000 Hz
Motor speed used /
uint32
Selects a signal to be connected to frequency output
1.
Freq out 1 source
11.55
0
None
Zero
1
1.1 Motor speed used (page 134)
Motor speed used
3
1.6 Output frequency (page 134)
.
Output frequency
4
Motor current
Parameters 183
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...