Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
- / uint32
Defines the rollover axis configuration.
If this parameter is set to 0, the master axis is linear
and the actual position (
) will be in its default range.
If
87.15 Master axis modulo numerator
is greater than
0, the ratio of
and
defines the range of
. This range is repeated when the target
position is set outside of the range. If the ratio of the
modulo range is set to 1, the range set by the feed
constant is repeated with each revolution of position
feedback. For more details, see section
.
Modulo range
numerator
86.18
1 = 1 / 1 = 1
Modulo range numerator.
0...2000000000
- / uint32
See parameter
Modulo range
denominator
86.19
1 = 1 / 1 = 1
Modulo range denominator.
0...2000000000
Forward / uint16
Defines the direction of the axis.
Axis direction
86.20
0
increases when the position signal
defined by
increases.
Forward
1
decreases when the position signal
defined by
increases. When
you use this option, make sure that you set the
parameter
86.25 Actual position tracking
to
.
Reverse
- / int32
Parameters
86.21 Load encoder scale numerator
and
86.22 Load encoder scale denominator
define a gear
function between the motor and load speeds.
86.21 Load encoder scale numerator
= Motor speed/Load
encoder speed
Load encoder scale
numerator
86.21
1 = 1 / 1 = 1
Numerator.
-2000000000...2000000000
- / int32
See parameter
86.21 Load encoder scale numerator
.
Load encoder scale
denominator
86.22
1 = 1 / 1 = 1
Denominator.
1...2000000000
- / real32
Defines a filter time for
Actual velocity filter
time
86.23
1000 = 1 ms / 1000 =
1 ms
Filter time.
0...3000 ms
Fault / uint16
Selects how the drive reacts to the loss of actual
position feedback (selected by
Axis feedback loss
action
86.24
0
The drive trips on a fault,
Fault
1
The drive generates a warning,
Warning
Disable / uint16
Enables and disables absolute position tracking during
power down.
Actual position
tracking
86.25
0
Actual position tracking is disabled.
Fault
1
Actual position tracking is enabled.
Enable
- / real32
Defines the value that is set as actual when homing is
successfully executed.
Homing preset
position
86.30
466 Parameters
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...