Router mode for BCU control unit
The BCU control unit of an inverter unit can be set to a “router mode” to allow the
control of locally-connected power units (for example, inverter modules) by another
BCU. Using the router mode and some hardware switching, it is possible to have
the same modules alternate between inverter and, for example, IGBT supply use.
The router mode involves connecting the two BCUs together by their PSL2 channels.
When router mode is active, the channels coming from the other BCU are forwarded
to the local modules.
The diagrams below show how the control of four converter modules can be
switched between two BCUs.
Note: For an example of how to switch converter modules between inverter and
IGBT supply use, see the
ACS880 IGBT supply control program firmware manual
(3AUA0000131562 [English]).
BCU 1 controlling all modules, BCU 2 in router mode
BCU 1
95.14 = 000Fh (1111b)
95.16 = Off
BCU 2
95.16 = On
95.17 = 1100b
CH1
CH2
CH3
CH4
CH1
CH2
CH3
CH4
Module 1
Module 2
Module 3
Module 4
BCU 2 controlling all modules, BCU 1 in router mode
Program features 127
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...