Transparent profile
ABB drives profile
Reference
Status Word bit 31
Reserved
10032
, bit 0
Reserved
10033
, bit 1
Reserved
10034
, bit 2
Reserved
10035
, bit 3
Reserved
10036
, bit 4
Reserved
10037
, bit 5
Reserved
10038
, bit 6
Reserved
10039
, bit 7
Reserved
10040
, bit 8
Reserved
10041
, bit 9
Reserved
10042
, bit 10
Reserved
10043
, bit 11
Reserved
10044
, bit 12
Reserved
10045
, bit 13
Reserved
10046
, bit 14
Reserved
10047
, bit 15
Reserved
10048
Error code registers (holding registers 400090…400100)
These registers contain information about the last query. The error register is
cleared when a query has finished successfully.
Description
Name
Reference
1 = Reset internal error registers (91…95).
Reset Error Registers
90
Function code of the failed query.
Error Function Code
91
Set when exception code 04h is generated (see
table above).
Error Code
92
•
00h No error
•
02h Low/High limit exceeded
•
03h Faulty Index: Unavailable index of an array
parameter
•
05h Incorrect Data Type: Value does not match
the data type of the parameter
•
65h General Error: Undefined error when
handling query
The last register (discrete input, coil, or holding
register) that failed to be read or written.
Failed Register
93
The last register that was written successfully.
Last Register Written Suc-
cessfully
94
The last register that was read successfully.
Last Register Read Suc-
cessfully
95
Fieldbus control through the embedded fieldbus interface (EFB) 625
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...