Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
Configuration of digital inputs and relay outputs.
Standard DI, RO
10
- / uint16
Displays the electrical status of digital inputs DIIL and
DI6…DI1. The activation/deactivation delays of the
DI status
10.1
inputs (if any are specified) are ignored. A filtering time
can be defined by parameter
.
Bits 0…5 reflect the status of DI1…DI6; bit 15 reflects
the status of the DIIL input. Example:
1000000000010011b = DIIL, DI5, DI2 and DI1 are on,
DI3, DI4 and DI6 are off.
This parameter is read-only.
- / uint16
Displays the status of digital inputs DIIL and DI6…DI1.
This word is updated only after activation/deactivation
DI delayed status
10.2
delays (if any are specified). A filtering time can be
defined by parameter
.
Bits 0…5 reflect the delayed status of DI1…DI6; bit 15
reflects the delayed status of the DIIL input.
This parameter is read-only.
- / uint16
The electrical statuses of the digital inputs can be
overridden for eg. testing purposes. A bit in parameter
DI force selection
10.3
is provided for each digital input,
and its value is applied whenever the corresponding
bit in this parameter is 1.
1 = Force DI1 to value of bit 0 of parameter
DI1
b0
1 = Force DI2 to value of bit 1 of parameter
DI2
b1
1 = Force DI3 to value of bit 2 of parameter
DI3
b2
1 = Force DI4 to value of bit 3 of parameter
DI4
b3
1 = Force DI5 to value of bit 4 of parameter
DI5
b4
1 = Force DI6 to value of bit 5 of parameter
DI6
b5
Reserved
b6…14
1 = Force DIIL to value of bit 15 of parameter
DIIL
b15
1 = 1
0000h…FFFFh
- / uint16
Contains the values that the digital inputs are forced
to when selected by
DI force data
10.4
Bit 0 is the forced value for DI1; bit 15 is the forced value
for the DIIL input.
Parameters 173
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...