Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
- / uint16
(Visible when
=
Displays the status of the digital input/outputs on the
extension module. The activation/deactivation delays
(if any are specified) are ignored. A filtering time (for
input mode) can be defined by parameter
Bit 0 indicates the status of DIO1.
Note: The number of active bits in this parameter
depends on the number of digital input/outputs on
the extension module.
Example: 1001b = DIO1 and DIO4 are on, remainder are
off.
This parameter is read-only.
DIO status
14.5
- / uint16
(Visible when
=
Displays the status of the digital input/outputs on the
extension module. The activation/deactivation delays
(if any are specified) are ignored. A filtering time (for
input mode) can be defined by parameter
Bit 0 indicates the status of DIO1.
Note: The number of active bits in this parameter
depends on the number of digital input/outputs on
the extension module.
Example: 1001b = DIO1 and DIO4 are on, remainder are
off.
This parameter is read-only.
DIO status
14.5
- / uint16
(Visible when
=
)
Displays the delayed status of the digital inputs on the
extension module. The word is updated only after
activation/deactivation delays (if any are specified).
Bit 0 indicates the status of DI1.
Note: The number of active bits in this parameter
depends on the number of digital inputs on the
extension module.
Example: 0101b = DI1 and DI3 are on, remainder are off.
This parameter is read-only.
DI delayed status
14.6
- / uint16
(Visible when
=
Displays the delayed status of the digital input/outputs
on the extension module. This word is updated only
after activation/deactivation delays (if any are
specified).
Bit 0 indicates the status of DIO1.
Note: The number of active bits in this parameter
depends on the number of digital input/outputs on
the extension module.
Example: 1001b = DIO1 and DIO4 are on, remainder are
off.
This parameter is read-only.
DIO delayed status
14.6
Parameters 199
Содержание ACS880 N5700 Series
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Страница 2: ......
Страница 4: ......
Страница 22: ...22 ...
Страница 28: ...28 ...
Страница 32: ...32 ...
Страница 60: ...60 ...
Страница 456: ...Def Type FbEq 16b 32b Description Name Range Selection No 100 1 1 1 Overriding value 0 001 100 000 456 Parameters ...
Страница 546: ...546 ...
Страница 604: ...604 ...
Страница 626: ...626 ...
Страница 640: ...640 ...
Страница 660: ...660 ...