Table 3-1 Drive Ratings, Model Numbers and Frame Sizes with 50 and 60 Hz Supply
Catalog Number
ACS880-01-
Frame
Size
Input
Rating
Max
Current
Output Ratings
Light-Overload Use
I
1N
I
max
I
LD
P
LD
A
A
A
kW
hp
U
N
= 208…240V
24A3-2+N5350
R2
24.3
28.6
23.1
5.5
7.5
031A-2+N5350
R3
31
41
29.3
7.5
10
046A-2+N5350
R4
46
64
44
11
15
061A-2+N5350
R4
61
76
58
15
20
075A-2+N5350
R5
75
104
71
18.5
25
087A-2+N5350
R5
87
122
83
22
30
115A-2+N5350
R6
115
148
109
30
40
145A-2+N5350
R6
145
178
138
37
50
170A-2+N5350
R7
170
247
162
45
60
206A-2+N5350
R7
206
287
196
55
75
274A-2+N5350
R8
274
362
260
75
100
U
N
= 380…415V
12A6-3+N5350
R1
12.6
16
12
5.5
7.5
017A-3+N5350
R2
17
21
16
7.5
10
025A-3+N5350
R2
25
29
24
11
15
032A-3+N5350
R3
32
42
30
15
20
038A-3+N5350
R3
38
54
36
18.5
25
045A-3+N5350
R4
45
64
43
22
30
061A-3+N5350
R4
61
76
58
30
40
072A-3+N5350
R5
72
104
68
37
50
087A-3+N5350
R5
87
122
83
45
60
105A-3+N5350
R6
105
148
100
55
75
145A-3+N5350
R6
145
178
138
75
100
169A-3+N5350
R7
169
247
161
90
125
206A-3+N5350
R7
206
287
196
110
150
246A-3+N5350
R8
246
350
234
132
200
293A-3+N5350
R8
293
418
278
160
225
363A-3+N5350
R9
363
498
345
200
275
430A-3+N5350
R9
430
545
400
200
350
Содержание ACS880+N5350
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 N5350 cooling tower drives User s guide ...
Страница 32: ...Terminal Specifications 4 7 3AXD50000011888 Figure 4 3 Cable Conduit Installation R6 R7 R8 R9 ...
Страница 193: ...13 20 Troubleshooting 3AXD50000011888 ...
Страница 201: ...B 2 Dimensions 3AXD50000011888 Figure B 1 Frame R1 IP21 UL Type 1 Frame R1 IP21 UL Type 1 3AUA0000097621 ...
Страница 202: ...Dimensions B 3 3AXD50000011888 Figure B 2 Frame R2 IP21 UL Type 1 Frame R2 IP21 UL Type 1 3AUA0000097691 ...
Страница 203: ...B 4 Dimensions 3AXD50000011888 Figure B 3 Frame R3 IP21 UL Type 1 Frame R3 IP21 UL Type 1 3AUA0000097847 ...
Страница 206: ...Dimensions B 7 3AXD50000011888 Figure B 6 R6 IP21 UL Type 1 Frame R6 IP21 UL Type 1 3AUA0000098321 ...
Страница 207: ...B 8 Dimensions 3AXD50000011888 Figure B 7 Frame R7 IP21 UL Type 1 Frame R7 IP21 UL Type 1 3AUA0000073149 ...
Страница 208: ...Dimensions B 9 3AXD50000011888 Figure B 8 Frame R8 IP21 UL Type 1 Frame R8 IP21 UL Type 1 3AUA0000073150 ...
Страница 209: ...B 10 Dimensions 3AXD50000011888 Figure B 9 Frame R9 IP21 UL Type 1 Frame R9 IP21 UL Type 1 3AUA0000073151 ...
Страница 211: ...C 2 CE Guidelines 3AXD50000011888 Figure C 1 Declaration of Conformity ...
Страница 212: ...CE Guidelines C 3 3AXD50000011888 ...
Страница 244: ...Ethernet IP Setup G 3 3AXD50000011888 3 Click on New Module 4 Select Module Type ETHERNET MODULE ...
Страница 246: ...Ethernet IP Setup G 5 3AXD50000011888 8 The ACS880 CTD Drive is now added to the PLC I O ...