4.1 Power Wire Gauge Range Specifications
Use copper conductors only.
Table 4-1 Power Wire Gauge Specification
Catalog Number
ACS880-01-
Frame Size
Metric
1)
US
2)
Cu Cable
Type Typical
AI Cable
Type Typical
Cu Cable
Type Typical
AI Cable
Type Typical
mm
2
mm
2
AWG/kcmil
AWG/kcmil
208…240V
04A6-2+N5350
R1
3 x 1.5
-
14
-
06A6-2+N5350
R1
3 x 1.5
-
14
-
07A5-2+N5350
R1
3 x 1.5
-
14
-
10A6-2+N5350
R1
3 x 1.5
-
14
-
16A8-2+N5350
R2
3 x 6
-
10
-
24A3-2+N5350
R2
3 x 6
-
10
-
031A-2+N5350
R3
3 x 10
-
8
-
046A-2+N5350
R4
3 x 16
3 x 35
6
-
061A-2+N5350
R4
3 x 25
3 x 35
4
-
075A-2+N5350
R5
3 x 35
3 x 50
3
-
087A-2+N5350
R5
3 x 35
3 x 70
3
-
115A-2+N5350
R6
3 x 50
3 x 70
1
-
145A-2+N5350
R6
3 x 95
3 x 120
2/0
-
170A-2+N5350
R7
3 x 120
3 x 150
3/0
-
206A-2+N5350
R7
3 x 150
3 x 240
250 MCM
-
274A-2+N5350
R8
-
-
-
-
380…415V
02A4-3+N5350
R1
3 x 1.5
-
14
-
03A3-3+N5350
R1
3 x 1.5
-
14
-
04A0-3+N5350
R1
3 x 1.5
-
14
-
05A6-3+N5350
R1
3 x 1.5
-
14
-
07A2-3+N5350
R1
3 x 1.5
-
14
-
09A4-3+N5350
R1
3 x 1.5
-
14
-
12A6-3+N5350
R1
3 x 1.5
-
14
-
017A-3+N5350
R2
3 x 6
-
10
-
025A-3+N5350
R2
3 x 6
-
10
-
032A-3+N5350
R3
3 x 10
-
8
-
038A-3+N5350
R3
3 x 10
-
8
-
045A-3+N5350
R4
3 x 16
3 x 35
6
-
061A-3+N5350
R4
3 x 25
3 x 35
4
-
072A-3+N5350
R5
3 x 35
3 x 50
3
-
087A-3+N5350
R5
3 x 35
3 x 70
3
-
105A-3+N5350
R6
3 x 50
3 x 70
1
-
145A-3+N5350
R6
3 x 95
3 x 120
2/0
-
169A-3+N5350
R7
3 x 120
3 x 150
3/0
-
206A-3+N5350
R7
3 x 150
3 x 240
250 MCM
-
246A-3+N5350
R8
2 x (3x70)
3)
2 x (3x95)
300 MCM
-
293A-3+N5350
R8
2 x (3x95)
3)
2 x (3x120)
2 x 3/0
-
363A-3+N5350
R9
2 x (3x120)
2 x (3x185)
2 x 4/0
-
430A-3+N5350
R9
2 x (3x150)
2 x (3x240)
2 x 250 MCM
-
Содержание ACS880+N5350
Страница 1: ... ABB INDUSTRIAL DRIVES ACS880 N5350 cooling tower drives User s guide ...
Страница 32: ...Terminal Specifications 4 7 3AXD50000011888 Figure 4 3 Cable Conduit Installation R6 R7 R8 R9 ...
Страница 193: ...13 20 Troubleshooting 3AXD50000011888 ...
Страница 201: ...B 2 Dimensions 3AXD50000011888 Figure B 1 Frame R1 IP21 UL Type 1 Frame R1 IP21 UL Type 1 3AUA0000097621 ...
Страница 202: ...Dimensions B 3 3AXD50000011888 Figure B 2 Frame R2 IP21 UL Type 1 Frame R2 IP21 UL Type 1 3AUA0000097691 ...
Страница 203: ...B 4 Dimensions 3AXD50000011888 Figure B 3 Frame R3 IP21 UL Type 1 Frame R3 IP21 UL Type 1 3AUA0000097847 ...
Страница 206: ...Dimensions B 7 3AXD50000011888 Figure B 6 R6 IP21 UL Type 1 Frame R6 IP21 UL Type 1 3AUA0000098321 ...
Страница 207: ...B 8 Dimensions 3AXD50000011888 Figure B 7 Frame R7 IP21 UL Type 1 Frame R7 IP21 UL Type 1 3AUA0000073149 ...
Страница 208: ...Dimensions B 9 3AXD50000011888 Figure B 8 Frame R8 IP21 UL Type 1 Frame R8 IP21 UL Type 1 3AUA0000073150 ...
Страница 209: ...B 10 Dimensions 3AXD50000011888 Figure B 9 Frame R9 IP21 UL Type 1 Frame R9 IP21 UL Type 1 3AUA0000073151 ...
Страница 211: ...C 2 CE Guidelines 3AXD50000011888 Figure C 1 Declaration of Conformity ...
Страница 212: ...CE Guidelines C 3 3AXD50000011888 ...
Страница 244: ...Ethernet IP Setup G 3 3AXD50000011888 3 Click on New Module 4 Select Module Type ETHERNET MODULE ...
Страница 246: ...Ethernet IP Setup G 5 3AXD50000011888 8 The ACS880 CTD Drive is now added to the PLC I O ...