Chapter 11 User
NWA1000 Series User’s Guide
95
Figure 60
Configuration > Object > User > Setting
The following table describes the labels in this screen.
Table 41 Configuration > Object > User > Setting
LABEL
DESCRIPTION
User Default Setting
Default Authentication
Timeout Settings
These authentication timeout settings are used by default when you create a new
user account. They also control the settings for any existing user accounts that are
set to use the default settings. You can still manually configure any user account’s
authentication timeout settings.
Edit
Double-click an entry or select it and click
Edit
to open a screen where you can
modify the entry’s settings.
#
This field is a sequential value, and it is not associated with a specific entry.
User Type
These are the kinds of user account the NWA1000 Series supports.
•
admin
- this user can look at and change the configuration of the NWA1000
Series
•
limited-admin
- this user can look at the configuration of the NWA1000 Series but
not to change it
•
user
- this is used for embedded RADIUS server and SNMPv3 user access
Lease Time
This is the default lease time in minutes for each type of user account. It defines the
number of minutes the user has to renew the current session before the user is
logged out.
Admin users renew the session every time the main screen refreshes in the Web
Configurator.
Reauthentication Time
This is the default reauthentication time in minutes for each type of user account. It
defines the number of minutes the user can be logged into the NWA1000 Series in
one session before having to log in again. Unlike
Lease Time
, the user has no
opportunity to renew the session without logging out.