Thick Paste Extruder workflow
145
15.4 Calibration
Press the "Home X" and
"Home Y" buttons.
Warning!
Do not press
the "Home Z" button.
Go back to the "Move"
page.
Use the "Move x,y,z"
buttons to maneuver the
Thick Paste syringe to be
1mm above the front left
corner of the table.
Choose your Gcode file
and press "NEXT".
Go to the "Calibrate"
option.
Press the "SET" button.
Choose "Thick Paste
printing".
Go back to the "main
menu" screen.
Enter the "New Job".
Enter the "Maintenance"
menu.
Go to the "Change Tool"
option.
Go to the "3D printing",