CNC milling workflow
126
detectors are installed, make sure they do not cause false alarms.
Health and safety instructions for handling CNC PRO Milling Toolhead.
General information.
• Use the ZMorph VX device with the CNC PRO toolhead in a separate room which can-
not be accessed by children or unauthorized persons,
• Do not put your hands in the workspace after turning on the spindle. The spindle ro-
tates at high speed and has rotating blades that can cause serious injuries,
• Use of the machine by unqualified personnel can lead to injury and/or damage to the
machine,
• If you notice any malfunctions of the machine, stop it immediately by pressing the re-
set button (red ring button on the right on the front panel of the machine) and contact
ZMorph Technical Support,
• Do not use a malfunctioning machine under the risk of voiding the warranty,
• Make sure that the material to be machined is firmly attached to the work platform
and cannot move in any direction. Failure to follow the instructions may result in injury
and/or damage to the machine,
• When using a ZMorph VX machine with the CNC PRO toolhead without covers, both
operators and bystanders must always wear safety goggles; failure to do so may re-
sult in eye damage.
Safety at work
• Do not place your hands in the workspace under any circumstances after starting the
spindle. Any exposure of the body to rotating parts of the machine can lead to serious
injury. It is therefore essential to use the device safely and in accordance with the in-
structions,
• The ZMorph VX machine on which the CNC PRO Toolhead is mounted and running
cannot be left unattended,
• The use and maintenance of the machine must always be carried out in the manner
described in the operating instructions,
• Under no circumstances should you open covers that conceal electronic components
of the machine when the power supply is connected. If there is a need for repairs or
an overhaul of components contact ZMorph Technical Support. For local repairs, the
housing may only be removed after the machine has been disconnected from the
power supply and the plug has been disconnected from the socket,
• Make sure the room ventilation is working properly,
• The workpieces and tools must be mounted in a stable manner at the correct loca-
tions. Avoid collision between the workpiece and the machine. Otherwise, the ma-