CALIBRATION
Data Separator Calibration
Perform the calibration as follows:
1.
Tu r n t he Computer on. Allow at least five minutes for
the Disk Controller Card to r e ach o p erating tempera-
ture.
2.
Ma k e sure the disk drives are not selected.
3.
Se t t he DVM's voltage range to 2 V. Attach the common
lead to GND and the positive lead to CP2.
4.
Adj u s t R2 (shown in Pictorial 6-5) for a reading of 1.400
V.
5.
Rem o ve the voltmeter test leads.
6.
Set t h e six-digit frequency counter to count 4 MHz.
7.
A tta c h t h e s h i eld lead to GN D a n d th e s ignal lead to
CP1.
8.
Adj u s t R1 (shown in Pictorial 6-5) for a reading of 4.000
MHz.
9.
Rep e a t Steps 2 through 8 until there is no further im-
provement and the 1.4 V and 4 MHz readings occur
simultaneously. There will be some (but not much) inter-
action between these adjustments.
10. R e m ove the test leads and turn the Computer off.
This completes the calibration procedure.
NOTE: Format the blank diskettes used in this procedure
again before you use them for recording files.
Summary of Contents for Z-100 Series
Page 2: ...This Document was scanned and contributed by...
Page 7: ......
Page 37: ......
Page 171: ...page 2 133 SEMICONDUCTOR IDENTIFICATION...
Page 322: ......
Page 390: ...R9 1 R4 Ri R1 TG43 PS U1 R 19 U18 U21 I Z 14 UaS U32 CIRCUIT I Shown from the c component...
Page 397: ...Page 7 1 5 1 4 Floppy Drives 7 2 Description Programming Cable Connections Operation 7 5 7 6...
Page 404: ......
Page 405: ...Page 8 1 Power Supply Power Line Considerations Specifications 8 2 8 3...
Page 411: ...page 9 3 REPLACEMENT PARTS LIST V s 1 s I t V p 10 ALL IN ONE...
Page 415: ...Page 9 7 ACE5fENT p4RTS L 45 44 43 46 61 42 60 40 50 52 I...
Page 417: ...page 9 9 REPLACEMENT PARTS LIST 1 4 9 io 20 1II l I i jj e e 1 I 17...
Page 419: ...Page 9 f E LACEMENT pRTS LIST 23 24 h 2S 26 28 29 L 41 40 C 3 0 I t tj t 3 4 Q t...
Page 426: ......