D-4
APPENDIX D
Conversion Table for Blue-Yellow
Decibels
Foot Lamberts
Apostilbs
(dB)
(Ft.-L)
(asb.)
0
6.0
65
5
1.9
20.6
10
0.6
6.5
15
0.19
2.6
20
0.06
0.65
25
0.019
0.26
30
0.006
0.065
35
0.0019
0.026
40
0.0006
0.0065
Blue-Yellow Specifications
Stimulus Color
440 nm (Blue)
Background Illumination Color
Shott OG-530 Filter (Yellow)
Background Brightness Level
100 cd/m
2
Stimulus Size
Goldmann V
Stimulus Duration
200 msec
References to Section 4: Blue-Yellow (SWAP) Perimetry
1. Johnson CA, Adams AJ, Casson EJ, Brandt JD: Blue-on-Yellow perimetry can predict the development of glaucomatous field loss, Arch Ophthalmol. 1993; 111:645-
650.
2. Sample PA, Taylor JDN, Martinez GA, Lusky M, Weinreb RN: Short-wavelength color visual fields in glaucoma suspects at risk. Am. J. Ophthalmol. 1993; 115:225-
233.
3. Johnson CA, Adams AJ, Casson EJ, Brandt JD: Progression of early glaucomatous visual field loss as detected by blue-on-yellow and standard white-on-white
perimetry. Arch. Ophthalmol. 1993; 111:651-656.
4. Sample PA, Weinreb RN: Progressive color visual field loss in glaucoma, Invest. Ophth & Vis. Sci., 33:6 pp. 2068 - 71, May 1992.
5. Johnson CA, Brandt JD, Khong AM, Adams AJ: Short-wavelength automated perimetry in low-, medium-, and high-risk ocular hypertensive eyes. Arch. Ophth. 113:70-
76, Jan.. 1995
6. Keltner JL, Johnson CA: Short-wavelength automated perimetry in neuro-ophthalmologic disorders. Arch. Ophthalmol. 113:475-481, April 1995.
7. Sample PA, Johnson CA, Haegerstrom-Portnoy G, Adams AJ: The optimum parameters for short-wavelength automated perimetry. J Glauc. 5:6, In Pres, 1996.
8. Sample PA, Martinez GA, Weinreb RN: Short-wavelength automated perimetry without lens density testing, A. J. Ophth, 18:632-641, Nov. 1994.
R E V . A 10 9/ 9 8 P N 47653
H U M P H R E Y F I E L D A N A L Y Z E R
I I
REV. B 02/03 PN 51680-1
HUMPHREY FIELD ANALYZER
II -
i
series
B-H Appendex.htp
3/14/03, 3:22 PM
10
Summary of Contents for HUMPHREY 720i
Page 1: ...HUMPHREY FIELD ANALYZER II i series USER S GUIDE Model 720i Model 740i Model 745i Model 750i...
Page 4: ......
Page 26: ...1 18 INTRODUCTION INSTRUMENT SETUP REV B 02 03 PN 51680 1 HUMPHREY FIELD ANALYZER II i series...
Page 116: ...6 8 TEST RELIABILITY REV B 02 03 PN 51680 1 HUMPHREY FIELD ANALYZER II i series...
Page 208: ...10 20 CUSTOM TESTING REV B 02 03 PN 51680 1 HUMPHREY FIELD ANALYZER II i series...
Page 284: ...12 14 CARE AND CLEANING REV B 02 03 PN 51680 1 HUMPHREY FIELD ANALYZER II i series...
Page 327: ......
Page 328: ......