INSTRUMENT
DECRIPTION
Carl Zeiss
Technical data
Axio Imager
30
430000-7344-001
M70-2-0020 e 06/2009
Transformer HBO 100
Operating environment ......................................................................................................... Closed room
Protection Class ........................................................................................................................................ I
Protection Type ................................................................................................................................. IP 20
Line voltage ............................................................................................................. 100 VAC ... 240 VAC
Line frequency ............................................................................................................................. 50/60 Hz
Power consumption when HBO 100 is used................................................................................... 155 VA
Fuses in accordance with IEC 127
Axio Imager microscope stand, manual............................................................T 5.0 A/H / 250V, 5x20 mm
Power supply VP232-2 for Axio Imager, mot....................................................... T 4.0 A / 250V, 5x20 mm
Transformer HBO 100.................................................................................................T 2.0 A/H, 5x20 mm
Light sources
Halogen lamp ........................................................................................................................ 12 V/100 W
Adjustment of light source .............................................................. continuous, approx. 0.7 to 12 V
Mercury vapor short-arc lamp ...............................................................................................HBO 103 W/2
Power consumption of HBO 103 W/2.....................................................................................100 W
Axio Imager, coded
Stand with manual stage focusing
Coarse drive ...........................................................................................................2 mm/revolution
Fine drive .............................................................................. 0.2 mm/revolution; 2 µm scale interval
Lifting range..................................................................................................................max. 25 mm
Height stop ..................................................................................................mechanically adjustable
Achromatic-aplanatic universal condenser 0.9 H D Ph DIC with
swivel-type front lens, achromatic-aplanatic 0.9 DIC,
for objective magnifications V
obj.
< 10x ................................................... front lens 0.9 swiveled out
for objective magnifications V
obj.
≥
10x ......................................................front lens 0.9 swiveled in
8-position turret disc
Objective change:
Manually ................................................ via 6-position or 7-position nosepiece, HD or HD DIC M27
Change of method modules
Manually ............................................................................................. via 6-position reflector turret