7-193
7.1 Parameters - Single
temperature version
Annex 1
Sensors Configuration Parameter Table
Label
Description
Udm
Value
P2P
Environmental probe presence
-
OFF
P3P
Evaporator air delivery probe presence
-
OFF
Csa
Cold room probe calibration
°C
°F
0
0
CF
Measure unit selection
°C
°F
C
F
Digital Input Management Table
Another column, present in cab command menu, indicates actual sensor state (ON/OFF) read by CPU board.
Label (Sensor)
Logic
Abilitation
J8 Input Pin
High Pressure Switch
Op
En
13
Low Pressure Switch
Op
En
2
Clixon
cl
En
14
Differential pressure switch
cl
En
1
Oil Pressure
cl
En
9
Electric Standby Selected
cl
En
7
Water Temp
cl
En
8
Set-Point Comm.
cl
Dis
5
Thermal Overload protection
cl
En
12
Door Open
cl
Dis
6
Door Microswitch
cl
En
15
Defrost Input
cl
Dis
4
Remote ON/OFF
Op
En
10
Digital Output Management Table
Another column, present in cab command menu, indicates actual device state (ON/OFF) managed by CPU.
Label (Device)
Mode
Set State
J9 Output Pin
Alarms
Aut
2
Heating
Aut
4
Evaporator Fans
Aut
5
High Speed
Aut
6
Electrical Motor
Aut
7
Partialization
Aut
8
Starter
Aut
10
Fuel Pump
Aut
12
Pre-heating
Aut
13
Alternator
Aut
14
Anti-Freeze
Man
OFF
9
Condenser Fans
Aut
15
Clutch
Man
OFF
3
Summary of Contents for un0 010
Page 1: ...0MAN295 USA WORKSHOPMANUAL un0...
Page 4: ......
Page 15: ......
Page 16: ......
Page 17: ...Section1 Generalinformation...
Page 19: ......
Page 30: ......
Page 31: ...Section2 Descriptionoftheunit...
Page 33: ......
Page 45: ...34 Description of the unit 2 2 Evaporating section...
Page 46: ......
Page 47: ...Section3 CoolingCircuit...
Page 94: ......
Page 95: ...Section4 DieselEngine...
Page 97: ......
Page 130: ......
Page 131: ...Section5 ElectronicsandWirings...
Page 135: ......
Page 146: ...135 5 2 Electronic Boards Electronics and wiring 5 2 Electronic Boards CPU board...
Page 150: ...139 5 2 Electronic Boards Electronics and wiring Relay Board...
Page 155: ...144 Electronics and wiring 5 2 Electronic Boards Low Voltage Wirings...
Page 156: ...145 5 2 Electronic Boards Electronics and wiring High Voltage Wirings...
Page 178: ......
Page 179: ...Section6 Alarms Troubleshooting...
Page 181: ......
Page 183: ...172 Alarms Troubleshooting 6 1 StandardAlarms A04 Low Pressure Switch...
Page 184: ...173 6 1 StandardAlarms Alarms Troubleshooting A07 Water Temperature A08 Door Microswitch...
Page 185: ...174 Alarms Troubleshooting 6 1 StandardAlarms A10 Oil Pressure...
Page 186: ...175 6 1 StandardAlarms Alarms Troubleshooting A11 High Pressure...
Page 188: ...177 6 1 StandardAlarms Alarms Troubleshooting A16 Engine Failure...
Page 189: ...178 Alarms Troubleshooting 6 1 StandardAlarms A17 Alternator Failure...
Page 190: ...179 6 1 StandardAlarms Alarms Troubleshooting A18 Water sensor error...
Page 195: ...184 Alarms Troubleshooting 6 3 Troubleshooting Unit does not start after blackout...
Page 196: ...185 6 3 Troubleshooting Alarms Troubleshooting Unit not performing...
Page 197: ......
Page 198: ......
Page 199: ...Annex1 Parameters...
Page 201: ......
Page 208: ......
Page 209: ......