YX3000 Senseless Vector Type Inverter Manual
- 90 -
15
:
VI
+
CI
-
control panel
▲
▲
、
▼key given
+
digital given P0.02
16
:
MAX
(
VI
,
CI
)
17
:
MIN
(
VI
,
CI
)
18
:
MAX
(
VI
,
CI
,
PLUSE
)
19
:
MIN
(
VI
,
CI
,
PLUSE
)
20
:
VI
,
CI availability except
,
VI prior
21: VI+Terminal UP/ DOWN
22: CI+Terminal UP/ DOWN
P3.01
Parameter
initialization setting
Range: LED unit’s digit 0~2
LED ten’s digit 0~2
00
LED unit’s digit
0
:
All parameters are allowed to be revised
1
:
All parameters are not allowed to be revised except this parameter itself
2
:
All parameters are not allowed to be revised except P0.02 parameter and this parameter
itself.
LED ten’s digit
0
:
inaction
1
:
Factory default reset
2
:
Clear history fault record
Note
:
(1) The factory default setting of this function code parameter is 0, that is all the
function code parameter are allowed to be revised
。
(2) After factory default reset, each place of this function code recovers to 0
automatically.
P3.02
Parameter copy
Range: 0, 1, 2
0
0
:
inaction
1
:
Parameter upload: upload function code parameter to remote control
2
:
Parameters download: download function code parameter from remote control