YX3000 Senseless Vector Type Inverter Manual
- 99 -
function selection
P4.06
Input terminal X7
function selection
Range: 0
~
30
0
P4.07
Input terminal X8
function selection
Range
:
0
~
30
0
The multifunctional input terminal X1~X8 provide various function. It can set the value of
P4.00~P4.07 to define the function of terminal X1~X8 shown as Table 6-1. Terminal X7 -FWD
terminal, X8 -REV terminal.
Table 6-1 Multifunctional input selection
content
function
content
Function
0
Idle terminal
19
Freq. control channel selection 1
1
Multi-stage speed terminal 1
20
Freq. control channel selection 2
2
Multi-stage speed terminal 2
21
Freq. control channel selection 3
3
Multi-stage speed terminal 3
22
Command switched to terminal
4
External FWD JOG control
input
23
Running command control mode
selection 1
5
External REV JOG control
input
24
Running command control mode
selection 2
6
Acc/Dec time terminal 1
25
Swing freq start mode selection
7
Acc/Dec time terminal 2
26
Swing freq running reset
8
Acc/Dec time terminal 3
27
Close loop invalid
9
3-wire control
28
Simple PLC running pause command
10
Free stop input
(
FRS
)
29
PLC invalid
11
External stop command
30
PLC reset in stopping state
12
Stopping DC brake input
command DB
31
Freq. switched to CI