YX3000 Senseless Vector Type Inverter Manual
- 112 -
P4.20
Analog output (AO2) gain
Range: 0.50
~
2.00
1.00
6-7 Output terminal indication
content
function
Indication range
0
Output freq.
0~limit freq
1
Output current
0
-
2×rated current
2
Output voltage
0
-
1.2×motor rated voltage
3
Bus bar voltage
0
-
800V
4
PID given
0~10V
5
PID feedback
0~10V
6
VI
0~10V
7
CI
0~10V/4~20mA
Ten’s
content
function
description
0
0
~
10V
Output voltage 0
~
10V
1
0
~
20mA
Output current 0
~
20mA
,
AO1jumper to 1
2
4
~
20mA
Output current 4
~
20mA
,
AO1
jumper to 1
As to AO analog output, if user wants to change measuring range or adjust meter tolerance,
it can be achieved by regulating the output gain.
P4.21
DO output terminal function
selection
Range: 0
~
7
0
Please refer to Table 6-7.
P4.22
DO max pulse output freq
Range: 0.1
~
20.0
(
Max.20K
)
10.0K