YX3000 Senseless Vector Type Inverter Manual
- 35 -
A
na
lo
g
ou
tp
ut
AO1
Analog output
AO1
Analog voltage/current output,
indicating 7quantities, choose
Voltage or current output by setting
JP2 jumper.
Factory default: voltage output
(Grounding: GND)
Current output range
:
4~20mA
Voltage output range
:
0~10V
AO2
Analog output
AO2
Analog voltage output, indicating
7quantities(Grounding: GND)
Voltage output range
:
0~10V
Runnin
g
control
FWD
Forward
running
Refer to chapter 6.5 P4.08
Couple isolated input
Input resistance:2KΩ
Max.
input frequency:200Hz
Input voltagerange:9~30V
REV
Reverse
running
M
ul
tif
un
ct
io
na
li
np
ut
te
rm
in
al
X1
Multifunctional
input terminal 1
Can be defineda smultifunctional
on-off input terminal by programming,
Referring to Chapter 6.5 P4.
(Common port:COM)
X2
Multifunctional
input terminal 2
X3
Multifunctional
input terminal 3
X4
Multifunctional
input terminal 4
X5
Multifunctional
input terminal 5
X6
Multifunctional
input terminal 6
Po
w
er
so
ur
ce
P24
+24Vpower
source
24V power (negative
terminal: COM)
10V
+10Vpower
source
10Vpower(negative terminal:
GND)
Max. output current: 50mA