YX3000 Senseless Vector Type Inverter Manual
- 92 -
。
P3.06
JOG running freq.
Range: 0.10
~
50.00Hz
5.00Hz
P3.07
JOG Acc time
Range: 0.1
~
60.0S
20.0S
P3.08
JOG Dec time
Range: 0.1
~
60.0S
20.0S
JOG frequency has the highest priority. In any stage, as long as there is a JOG command
input, the inverter will switch to JOG frequency running by JOG Acc/Dec time immediately,
which is shown as Fig.6-14
JOG Acc time is the time for inverter accelerating from 0 to upper limit freq.
JOG Dec time is the time for inverter decelerating from upper limit freq. to 0.