3
JOHNSON CONTROLS
FORM 100.50-NOM6 (1207)
CHANGEABILITY OF THIS DOCUMENT
In complying with JOHNSON CONTROLS’s policy
for continuous prod uct improvement, the in for ma tion
con tained in this doc u ment is subject to change without
notice. While JOHNSON CONTROLS makes no
com mit ment to update or provide current in for ma tion
au to mat i cal ly to the manual owner, that in for ma tion, if
ap pli ca ble, can be ob tained by con tact ing the nearest
JOHNSON CONTROLS Applied Systems offi ce.
It is the responsibility of operating/service personnel
to verify the ap pli ca bil i ty of these doc u ments to the
equip ment in question. If there is any question in
the mind of operating/service personnel as to the
applicability of these doc u ments, then prior to work ing
on the equip ment, they should verify with the owner
whether the equip ment has been modifi ed and if current
literature is avail able.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Base
Type
Refrigerant
Supply
Openings
Return
Openings
Design Special
Y
:YORK
5
0
:50 Ton Capacity
:208/3/60
P
:Packaged Rooftop
0
5
1
:51 Ton Capacity
C :R-22
:230/3/60
A
:Air Cooled
0
6
0
:60 Ton Capacity
E :R-410A
4
6
:460/3/60
L
:Scroll
0
6
1
:61 Ton Capacity
5
8
:575/3/60
4
0
:380/3/60
4
5
:400/3/50
F :Full Modulating Gas Heat SS Staged HX
Voltage
2
5
X :Standard
S :Special P
A :Standard
B :Special P
N :Staged Natural Gas Heat
G :Staged Natural Gas Heat SS HX
M :Full Modulating Gas Heat
E :Electric Heat
H :Hot Water Heat
S :Steam Heat
F :Flexsys
C :Cooling Only
YPAL050-061
C :Constant Volume
V :VAV, VFD
Product
Nominal Capacity
Application
0
B :R-407C
B :Bottom Supply
L :Left Supply
R :Right Supply
B :Bottom Return
R :Rear Return
S :Side Return
F :Revision Level F
BASE MODEL NUMBER
NOMENCLATURE
LD13270
Summary of Contents for ECO2 YPAL 050
Page 62: ...62 JOHNSON CONTROLS FORM 100 50 NOM6 1207 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 113: ...113 JOHNSON CONTROLS FORM 100 50 NOM6 1207 6 ECONOMIZER EXHAUST LD13018...
Page 114: ...114 JOHNSON CONTROLS FORM 100 50 NOM6 1207 User Interface Control Center FANS LD13019...
Page 115: ...115 JOHNSON CONTROLS FORM 100 50 NOM6 1207 6 COOLING SETUP LD13020...
Page 117: ...117 JOHNSON CONTROLS FORM 100 50 NOM6 1207 6 HEATING SETUP LD13022...
Page 119: ...119 JOHNSON CONTROLS FORM 100 50 NOM6 1207 6 SYSTEM OPTIONS LD13024...
Page 121: ...121 JOHNSON CONTROLS FORM 100 50 NOM6 1207 6 INPUTS COMFORT DEMAND VENTILATION LD13014 LD13026...
Page 125: ...125 JOHNSON CONTROLS FORM 100 50 NOM6 1207 6 ALARMS LD13031...