5-107
IM 701730-17E
Commands
5
:TRIGger:PATTern:CONDition
Function
Sets the trigger condition when using the
pattern trigger or queries the current setting.
Syntax
:TRIGger:PATTern:CONDition
{ENTer|EXIT|FALSe|TRUE}
:TRIGger:PATTern:CONDition?
Example
:TRIGGER:PATTERN:CONDITION ENTER
:TRIGGER:PATTERN:CONDITION? ->
:TRIGGER:PATTERN:CONDITION ENTER
Description
Select the condition from
{ENTer|EXIT}
when
“
:TRIGger:PATTERN:CLOCk:SOURce NONE
”
is specified and from
{FALSe|TRUE}
,
otherwise.
:TRIGger:POSition
Function
Sets the trigger position or queries the current
setting.
Syntax
:TRIGger:POSition {<NRf>}
:TRIGger:POSition?
<NRf>=0 to 100 (%, 0.1 steps)
Example
:TRIGGER:POSITION 50
:TRIGGER:POSITION? ->
:TRIGGER:POSITION 50.000
:TRIGger:SCOunt (Single (N) Count)
Function
Sets the number of times the trigger is activated
when the trigger mode is set to Single (N) or
queries the current setting.
Syntax
:TRIGger:SCOunt {<NRf>}
:TRIGger:SCOunt?
<NRf>=1 to 2048
Example
:TRIGGER:SCOUNT 100
:TRIGGER:SCOUNT? ->
:TRIGGER:SCOUNT 100
:TRIGger[:SIMPle]?
Function
Queries all settings related to the simple trigger.
Syntax
:TRIGger:SIMPle?
Example
:TRIGGER:SIMPLE? ->
:TRIGGER:SIMPLE:SOURCE 1;
LEVEL 0.0E+00;SLOPE RISE;
COUPLING DC;HFREJECTION OFF;
HYSTERESIS LOW
:TRIGger[:SIMPle]:COUPling
Function
Sets the trigger coupling for the simple trigger
or queries the current setting.
Syntax
:TRIGger[:SIMPle]:COUPling {AC|DC}
:TRIGger[:SIMPle]:COUPling?
Example
:TRIGGER:SIMPLE:COUPLING DC
:TRIGGER:SIMPLE:COUPLING? ->
:TRIGGER:SIMPLE:COUPLING DC
Description
Setting/Querying is not possible when the
trigger source is set to “EXTernal” or “LINE.”
:TRIGger[:SIMPle]:HFRejection
(HighFrequencyREJECTION)
Function
Turns the low-pass filter (HF rejection) for the
trigger signal ON/OFF or queries the current
setting.
Syntax
:TRIGger[:SIMPle]:HFRejection
{OFF|<Frequency>}
:TRIGger[:SIMPle]:HFRejection?
<Frequency>=20 MHz, 15 kHz
Example
:TRIGGER:SIMPLE:HFREJECTION 20MHz
:TRIGGER:SIMPLE:HFREJECTION? ->
:TRIGGER:SIMPLE:HFREJECTION
20.0E+06
Description
Setting/Querying is not possible when the
trigger source is set to “EXTernal” or “LINE.”
:TRIGger[:SIMPle]:HYSTeresis
Function
Sets the hysteresis on the search level of the
simple trigger or queries the current setting.
Syntax
:TRIGger[:SIMPle]:HYSTeresis
{HIGH|LOW}
:TRIGger[:SIMPle]:HYSTeresis?
Example
:TRIGGER:SIMPlE:HYSTERESIS HIGH
:TRIGGER:SIMPlE:HYSTERESIS? ->
:TRIGGER:SIMPlE:HYSTERESIS HIGH
Description
Setting/Querying is not possible when the
trigger source is set to “EXTernal” or “LINE.”
:TRIGger[:SIMPle]:LEVel
Function
Sets the trigger level of the channel specified
with the “
:TRIGger[:SIMPle]:SOURce
”
command or queries the current setting.
Syntax
:TRIGger[:SIMPle]:LEVel {<voltage>}
:TRIGger[:SIMPle]:LEVel?
<voltage>=See the User’s Manual.
Example
:TRIGGER:SIMPLE:LEVEL 0V
:TRIGGER:SIMPLE:LEVEL? ->
:TRIGGER:SIMPLE:LEVEL 0.000E+00
Description
• Setting/Querying is not possible when the
trigger source is set to “LINE.”
• When set to the current probe, sets the
<Current> value or queries the current
setting.
:TRIGger[:SIMPle]:PROBe
Function
Sets the probe when the trigger source is set to
“EXTernal” or queries the current setting.
Syntax
:TRIGger[:SIMPle]:PROBe {<NRf>}
:TRIGger[:SIMPle]:PROBe?
<NRf>=1, 10
Example
:TRIGGER:SIMPLE:PROBE 1
:TRIGGER:SIMPLE:PROBE ->
:TRIGGER:SIMPLE:PROBE 1
Description
Setting/Querying is not possible unless the
trigger source is set to “EXTernal.”
:TRIGger[:SIMPle]:RANGe
Function
Sets the input range for the external trigger
andqueries the current setting. (DL1720E only)
Syntax
:TRIGger[:SIMPle]:RANGe {<voltage>}
:TRIGger[:SIMPle]:RANGe?
<NRf>=1 to 100 V
Example
:TRIGGER:SIMPLE:RANGE 1V
:TRIGGER:SIMPLE:RANGE? ->
:TRIGGER:SIMPLE:RANGE 1.0E+00
Description
Setting/Querying is not possible unless
thetrigger source is set to “EXTernal.”
5.30 TRIGger Group