ACQuire Group
:ACQuire?
Queries all settings related to waveform acquisition.
5-16
:ACQuire:AVERage?
Queries all settings related to averaging.
5-16
:ACQuire:AVERage:COUNt
Sets the number of waveform acquisitions during averaging or queries the
current setting.
5-16
:ACQuire:AVERage:EWEight
Sets the attenuation constant for exponential averaging or queries the
current setting.
5-16
:ACQuire:CLOCk
Sets the time base or queries the current setting.
5-16
:ACQuire:COUNt
Sets the number of waveform acquisitions during normal mode, average
mode, and box average or queries the current setting.
5-16
:ACQuire:INTerleave
Turns the interleave mode ON/OFF or queries the current setting.
5-16
:ACQuire:MODE
Sets the waveform acquisition mode or queries the current setting.
5-16
:ACQuire:REPetitive
Turns the repetitive sampling mode ON/OFF or queries the current setting.
5-16
:ACQuire:RLENgth
Sets the record length or queries the current setting.
5-16
ASETup Group
:ASETup:EXECute
Executes auto setup.
5-17
:ASETup:UNDO
Cancels the previous auto setup operation.
5-17
CALibrate Group
:CALibrate?
Queries all settings related to calibration.
5-17
:CALibrate:DESKew?
Queries all settings related to skew compensation.
5-17
:CALibrate:DESKew:MODE
Turns the skew compensation ON/OFF or queries the current setting.
5-17
:CALibrate:DESKew:TARGet
Sets the channel on which skew compensation is to be performed or
queries the current setting.
5-17
:CALibrate:DESKew:TIME
Sets the skew adjustment time that are common to all channels or queries
the current setting.
5-17
:CALibrate[:EXECute]
Executes the calibration.
5-18
:CALibrate:MODE
Turns auto calibration ON/OFF or queries the current setting.
5-18
CHANnel Group
:CHANnel<x>?
Queries all settings related to the vertical axis of the channel.
5-20
:CHANnel<x>:BWIDth
Sets the input filter of the channel or queries the current setting.
5-20
:CHANnel<x>:COUPling
Sets the input coupling of the channel or queries the current setting.
5-20
:CHANnel<x>:DISPlay
Turns ON/OFF the channel or queries the current setting.
5-20
:CHANnel<x>:LABel
Sets the waveform label of channel or queries the current setting.
5-20
:CHANnel<x>:LSCale?
Queries all settings related to the linear scaling of the channel.
5-20
:CHANnel<x>:LSCale:AVALue
Sets scaling coefficient A or queries the current setting.
5-20
:CHANnel<x>:LSCale:BVALue
Sets offset value B or queries the current setting.
5-20
:CHANnel<x>:LSCale:MODE
Turns ON/OFF the linear scaling or queries the current setting.
5-20
:CHANnel<x>:LSCale:UNIT
Sets the unit of the value after it is scaled or queries the current setting.
5-20
:CHANnel<x>:MODE
Turns ON/OFF the display of the channel or queries the current setting.
5-21
:CHANnel<x>:OFFSet
Sets the offset voltage of the channel or queries the current setting.
5-21
:CHANnel<x>:POSition
Sets the vertical position of the channel or queries the current setting.
5-21
:CHANnel<x>:PROBe
Sets the probe attenuation/current-to-voltage conversion ratio of the
channel or queries the current setting.
5-21
:CHANnel<x>:VARiable
Sets the voltage sensitivity of the channel in 0.01 steps of the V/div
setting or queries the current setting.
5-21
:CHANnel<x>:VDIV
Sets the voltage sensitivity (V/div) of the channel or queries the current
setting.
5-21
CLEar Group
:CLEar
Clears the trace.
5-22
COMMunicate Group
:COMMunicate?
Queries all settings related to communications.
5-23
:COMMunicate:HEADer
Sets whether or not to add a header to the response data or queries the
current setting.
5-23
:COMMunicate:LOCKout
Sets or clears the local lockout.
5-23
:COMMunicate:OPSE
Sets the overlap commands that are subject to
*OPC
,
*OPC?
, and
*WAI
or
queries the current setting.
5-24
:COMMunicate:OPSR?
Queries the operation pending status register value.
5-24
5.1 A List of Commands