5-7
IM 701730-17E
Commands
5
Command
Function
Page
MATH Group
:MATH<x>?
Queries all settings related to computations.
5-64
:MATH<x>:BINary?
Queries all settings related to binary computations.
5-64
:MATH<x>:BINary:{CHANnel<x>|MATH1}
Sets the threshold levels of the channel for binary computation or queries the
current setting.
5-64
:MATH<x>:DISPlay
Sets whether or not to display computation waveforms or queries the current
setting.
5-64
:MATH<x>:FFT?
Queries all settings related to the FFT.
5-64
:MATH<x>:FFT:POINts
Sets the number of points for the FFT or queries the current setting.
5-64
:MATH<x>:FFT:SPOint
Sets the start point of the FFT or queries the current setting.
5-64
:MATH<x>:FFT:WINDow
Sets the window function of the FFT or queries the current setting.
5-64
:MATH<x>:INTegral?
Queries all settings related to integration.
5-64
:MATH<x>:INTegral:SPOint
Sets the start point of the integration or queries the current setting.
5-64
:MATH<x>:LABel
Sets the label of the computation waveform or queries the current setting.
5-65
:MATH<x>:OPERation
Sets the type of computation or queries the current setting.
5-65
:MATH<x>:SCALe?
Queries all settings related to the scale conversion for normal computation.
5-65
:MATH<x>:SCALe:CENTer
Sets the center value of the scale conversion for normal computation or
queries the current setting.
5-65
:MATH<x>:SCALe:MODE
Sets the scale conversion method for normal computation or queries the
current setting.
5-65
:MATH<x>:SCALe:SENSitivity
Sets the span from the center of the scale conversion for normal computation
or queries the current setting.
5-65
:MATH<x>:SMOothing
Turns smoothing ON/OFF for normal computation or queries the current
setting.
5-65
:MATH<x>:UNIT
Sets the unit to be added to the computed result for normal computation or
queries the current setting.
5-65
MEASure Group
:MEASure?
Queries all settings related to the automated measurement of waveform
parameters.
5-69
:MEASure:AMODe
Sets the normal automated measurement of parameters (NORMal) and the
automated measurement of parameters on dual areas (AREA2) or queries
the current setting.
5-70
:MEASure:{CHANnel<x>|MATH<x>}?
Queries the ON/OFF state of every parameter of the waveform.
5-71
:MEASure:{CHANnel<x>|MATH<x>}:ALL
Turns ON/OFF collectively the automated measurement parameters of all
waveform parameters of the waveform.
5-71
:MEASure:{CHANnel<x>|MATH<x>}:COPY
Copies the ON/OFF setting of the automated measurement parameters of
waveform parameters of the specified waveform to all other waveforms.
5-71
:MEASure:{CHANnel<x>|MATH<x>}:DELay?
Queries all settings related to the delay between waveforms.
5-71
:MEASure:{CHANnel<x>|MATH<x>}:DELay:MEASure?
Queries all settings of the measured waveform in the delay measurement
between waveforms.
5-71
:MEASure:{CHANnel<x>|MATH<x>}:DELay:MEASure:COUNt
Sets the edge detection count of the measured waveform in the delay
measurement between waveforms or queries the current setting.
5-71
:MEASure:{CHANnel<x>|MATH<x>}:DELay:MEASure:SLOPe
Sets the slope of the measured waveform in the delay measurement
between waveforms or queries the current setting.
5-71
:MEASure:{CHANnel<x>|MATH<x>}:DELay:REFerence?
Queries all settings of the reference waveform in the delay measurement
between waveforms.
5-72
:MEASure:{CHANnel<x>|MATH<x>}:DELay:REFerence:COUNt
Sets the edge detection count of the reference waveform in the delay
measurement between waveforms or queries the current setting.
5-72
:MEASure:{CHANnel<x>|MATH<x>}:DELay:REFerence:SLOPe
Sets the slope of the reference waveform in the delay measurement between
waveforms or queries the current setting.
5-72
:MEASure:{CHANnel<x>|MATH<x>}:DELay:REFerence:SOURce
Sets the reference of the delay measurement between waveforms to the
trigger point or the waveform or queries the current setting.
5-72
:MEASure:{CHANnel<x>|MATH<x>}:DELay:REFerence:TRACe
Sets the trace of the reference waveform in the delay measurement between
waveforms or queries the current setting.
5-72
5.1 A List of Commands