11-4
IM CA150E
500 mV
DCV
measurement
Pulse
measurement
TC input
RTD input
Loop power
supply
20 mA
DCmA
measurement
100 Hz
1000 Hz
10 kHz
CPM
CPH
K
E
J
T
N
L
U
R
S
B
PT100
JPT100
0 to ±500.000 mV
0 to ±20.000 mA
1.00 to 110.00 Hz
1.0 to 1100.0 Hz
0.001 to 11.000 kHz
0 to 100000 CPM
0 to 100000 CPH
-200.0 to 1372.0 °C
-200.0 to 1000.0 °C
-200.0 to 1200.0 °C
-200.0 to 400.0 °C
-200.0 to 1300.0 °C
-200.0 to 900.0 °C
-200.0 to 400.0 °C
0 to 1768 °C
0 to 1768 °C
600 to 1820 °C
-200.0 to 850.0 °C
-200.0 to 500.0 °C
±(0.02% + 50 µV)
±(0.025% + 4 µA)
±2 dgt
––
––
±(0.05% + 1.5 °C)
/ -100.0 °C or more
±(0.05% + 2 °C)
/ -100.0 °C or less
±(0.05% + 2 °C)
/ 100 °C or more
±(0.05% + 3 °C)
/ 100 °C or less
±(0.05% + 2 °C)
However, 600 to 1000 °C
±(0.05% + 3 °C)
±(0.05% + 0.6 °C)
24 V ±2 V
Input resistance: 1000 M
Ω
or greater.
Input resistance:
Approx. 1 M
Ω
Input resistance:
Approx. 20
Ω
or less
Measurement current:
Approx. 1 mA
Measurement current:
Approx. 100 µA
Measurement current:
Approx. 10 µA
Maximum input: 30 Vpeak
Sensitivity: 0.5 Vp-p or
greater Input resistance:
Approx. 100
kΩ
Contact input: Max. 100 Hz
Maximum current: 22 mA
10 µV
5 V
0 to ±5.0000 V
±(0.02% + 0.5 mV)
0.1 mV
35 V
0 to ±35.000 V
±(0.025% + 5 mV)
1 mV
Range
Measurement
Range
Accuracy
Remarks
Resolution
1 µA
500 Ω
Resistance
measurement
0 to 500.00
Ω
±(0.055% + 0.075
Ω
)
0.01
Ω
5
kΩ
0 to 5.0000
kΩ
±(0.055% + 0.75
Ω
)
0.1
Ω
50 k
Ω
0 to 50.000
kΩ
±(0.055% + 10
Ω
)
1
Ω
100 mA
0 to ±100.00 mA
±(0.04% + 30 µA)
10 µA
0.01 Hz
0.1 Hz
0.001 kHz
1 CPM
1 CPH
0.1 °C
1 °C
0.1 °C
––
––
––
––
*4
*4
*5
Measurement
Accuracy = ± (% of r µV, mV, µA,
Ω
, dgt, °C) at 23±5°C
Temperature coefficient: When in the ranges of 0≤T<18°C and 28<T≤40°C,
add the accuracy shown above ×(1/10)/°C.
The above accuracy ranges are for values obtained after the instrument has been
left for two hours after charging ends (or is stopped).
*4: When using three-wire method (3W).
*5:
In the case of a load during source output, accuracy can be affected by internal heat.
Add as a coefficient the temperature of the part of the value obtained with the
temperature monitor function that exceeds 23±5°C.
(The temperature monitor function is a function for displaying the temperature
measured with the built-in RJ sensor.)
About Accuracy during Charging
Accuracy is affected by the internal heat during charging or immediately after
charging ends (is stopped). Refer to the accuracy values shown in
"Measurement during Charging" on the next page.
11. Specifications