16.1 List of Parameters
16.1.2 List of Parameters
16-19
16
Parameter and Object Lists
Pn416
(2416 hex)
2
Torque-Related Func-
tion Selections 2
0000 hex to
1111 hex
–
0000
hex
All
Immedi-
ately
Setup
Pn417
(2417 hex)
2
Third Stage Notch Filter
Frequency
50 to 5,000
1 Hz
5000
All
Immedi-
ately
Tuning
Pn418
(2418 hex)
2
Third Stage Notch Filter
Q Value
50 to 1,000
0.01
70
All
Immedi-
ately
Tuning
Pn419
(2419 hex)
2
Third Stage Notch Filter
Depth
0 to 1,000
0.001
0
All
Immedi-
ately
Tuning
Pn41A
(241A hex)
2
Fourth Stage Notch Fil-
ter Frequency
50 to 5,000
1 Hz
5000
All
Immedi-
ately
Tuning
Pn41B
(241B hex)
2
Fourth Stage Notch Fil-
ter Q Value
50 to 1,000
0.01
70
All
Immedi-
ately
Tuning
Pn41C
(241C hex)
2
Fourth Stage Notch Fil-
ter Depth
0 to 1,000
0.001
0
All
Immedi-
ately
Tuning
Pn41D
(241D hex)
2
Fifth Stage Notch Filter
Frequency
50 to 5,000
1 Hz
5000
All
Immedi-
ately
Tuning
Pn41E
(241E hex)
2
Fifth Stage Notch Filter
Q Value
50 to 1,000
0.01
70
All
Immedi-
ately
Tuning
Pn41F
(241F hex)
2
Fifth Stage Notch Filter
Depth
0 to 1,000
0.001
0
All
Immedi-
ately
Tuning
Pn423
(2423 hex)
2
Speed Ripple Compen-
sation Selections
0000 hex to
1111 hex
–
0000
hex
Rotary
−
Setup
Pn424
(2424 hex)
2
Torque Limit at Main Cir-
cuit Voltage Drop
0 to 100
1%
*1
50
All
Immedi-
ately
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Notch Filter Selection 3
0
Disable third stage notch filter.
1
Enable third stage notch filter.
n.
X
Notch Filter Selection 4
0
Disable fourth stage notch filter.
1
Enable fourth stage notch filter.
n.
X
Notch Filter Selection 5
0
Disable fifth stage notch filter.
1
Enable fifth stage notch filter.
n.X
Reserved parameter (Do not change.)
n.
X
Speed Ripple Compensation Function Selection
When
Enabled
0
Disable speed ripple compensation.
Immedi-
ately
1
Enable speed ripple compensation.
n.
X
Speed Ripple Compensation Information Disagreement Warning Detec-
tion Selection
When
Enabled
0
Detect A.942 alarms.
After
restart
1
Do not detect A.942 alarms.
n.
X
Speed Ripple Compensation Enable Condition Selection
When
Enabled
0
Speed reference
After
restart
1
Motor speed
n.X
Reserved parameter (Do not change.)