4.7 Connecting Dynamic Brake Resistors
4.7.1 Terminal Symbols and Terminal Names
4-37
4
W
iring and Connecting SER
VOP
ACKs
4.7
Connecting Dynamic Brake Resistors
A connector or terminal block is used to wire a Dynamic Brake Resistor.
4.7.1
Terminal Symbols and Terminal Names
4.7.2
Connecting a Dynamic Brake Resistor
•
Required Items
1.
Prepare the connector that is provided with the SERVOPACK.
2.
Remove the lead wire from between D2 and D3.
CAUTION
Wire all connections correctly according to the following table.
There is a risk of SERVOPACK failure or fire if incorrect wiring is performed.
SERVOPACK
Model
Terminal
Symbols
Terminal Name
Specification
SGD7S-1R9D,
-3R5D, -5R4D,
-8R4D, -120D,
-170D
D1, D2
Dynamic Brake Resis-
tor terminals
These terminals are connected to an External
Dynamic Brake Resistor.
WARNING
Wire the Dynamic Brake Resistor correctly. Do not connect the following terminals directly
to each other: D1 and D2.
There is a risk of burning in the SERVOPACK or Servomotor, damage to the machine, or injury.
CAUTION
Mount Dynamic Brake Resistors only on nonflammable materials. Do not mount them on or
near any flammable material.
There is a risk of fire.
Required Item
Remarks
Phillips or flat-blade
screwdriver
Commercially available screwdriver with a tip thickness of 0.6 mm and tip width of
3.5 mm