2.1 Ratings and Specifications
2.1.3 Specifications
2-6
Displays/Indicators
CHARGE, PWR, RUN, ERR, and L/A (A and B) indicators, and one-digit
seven-segment display
EtherCAT Communications Setting
Switches
EtherCAT secondary address (S1 and S2), 16 positions
EtherCAT
Communi-
cations
Applicable Communi-
cations Standards
IEC 61158 Type 12, IEC 61800-7 CiA402 Drive Profile
Physical Layer
100BASE-TX (IEEE 802.3)
Communications
Connectors
CN6A (RJ45): EtherCAT signal input connector
CN6B (RJ45): EtherCAT signal output connector
Cable
Category 5, 4 shielded twisted pairs
*
The cable is automatically detected with AUTO MDIX.
Sync Manager
SM0: Mailbox output, SM1: Mailbox input, SM2: Process data output,
and SM3: Process data input
FMMU
FMMU 0: Mapped in process data output (RxPDO) area.
FMMU 1: Mapped in process data input (TxPDO) area.
FMMU 2: Mapped to mailbox status.
EtherCAT
Commands
(Data Link Layer)
APRD, FPRD, BRD, LRD, APWR, FPWR, BWR, LWR, ARMW, and
FRMW (APRW, FPRW, BRW, and LRW commands are not supported.)
Process Data
Assignments can be changed with PDO mapping.
Mailbox (CoE)
Emergency messages, SDO requests, SDO responses, and SDO infor-
mation (TxPDO/RxPDO and remote TxPDO/RxPDO are not supported.)
Distributed Clocks
Free-Run Mode and DC Mode (Can be switched.)
Applicable DC cycles: 125 μs to 4 ms in 125-μs increments
Slave Information
Interface
256 bytes (read-only)
Indicators
EtherCAT communications in progress: Link/Activity x 2
EtherCAT communications status: RUN x 1
EtherCAT error status: ERR x 1
CiA402 Drive Profile
•
Homing Mode
•
Profile Position Mode
•
Interpolated Position Mode
•
Profile Velocity Mode
•
Profile Torque Mode
•
Cyclic Synchronous Position Mode
•
Cyclic Synchronous Velocity Mode
•
Cyclic Synchronous Torque Mode
•
Touch Probe Function
•
Torque Limit Function
Analog Monitor (CN5)
Number of points: 2
Output voltage range:
±
10 VDC (effective linearity range:
±
8 V)
Resolution: 16 bits
Accuracy:
±
20 mV (Typ)
Maximum output current:
±
10 mA
Settling time (
±
1%): 1.2 ms (Typ)
Dynamic Brake (DB)
*3
Activated when a servo alarm or overtravel (OT) occurs, or when the
power supply to the main circuit or servo is OFF.
Regenerative Processing
Built-in
Refer to the catalog for details.
Overtravel (OT) Prevention
Stopping with dynamic brake, deceleration to a stop, or coasting to a
stop for the P-OT (Forward Drive Prohibit) or N-OT (Reverse Drive Pro-
hibit) signal
Protective Functions
Overcurrent, overvoltage, low voltage, overload, regeneration error, etc.
Utility Functions
Gain adjustment, alarm history, jogging, origin search, etc.
Continued on next page.
Continued from previous page.
Item
Specification