16.2 Object List
16-36
2751 hex
ZONE table negative side boundary position (ZONE N)
0
Number of entries
USINT
RO
No
No
16
–
–
–
–
1
ZONE ID0
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA02
2
ZONE ID1
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA06
3
ZONE ID2
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA0A
4
ZONE ID3
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA0E
5
ZONE ID4
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA12
6
ZONE ID5
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA16
7
ZONE ID6
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA1A
8
ZONE ID7
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA1E
9
ZONE ID8
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA22
10
ZONE ID9
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA26
11
ZONE ID10
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA2A
12
ZONE ID11
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA2E
13
ZONE ID12
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA32
14
ZONE ID13
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA36
15
ZONE ID14
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA3A
16
ZONE ID15
DINT
RW
No
Yes
0
-2147483648
2147483647
Pos.
unit
PnA3E
2752 hex
0
ZONE output signal
selection 1
USINT
RW
No
Yes
0
0000
0xFFFF
–
PnBA0
2753 hex
0
ZONE output signal
selection 2
USINT
RW
No
Yes
0
0000
0x000F
–
PnBA1
27C0 hex
Interpolation data record for 1st profile
0
Number of entries
USINT
RO
No
No
254
–
–
–
–
1 to 254
1st set-point to
254 set-point
DINT
RW
No
No
0
-2147483648
2147483647
–
–
27C1 hex
Interpolation data record for 2nd profile
0
Number of entries
USINT
RO
No
No
254
–
–
–
–
1 to 254
1st set-point to
254 set-point
DINT
RW
No
No
0
-2147483648
2147483647
–
–
27E0 hex
–
Diag. mode
UINT
RW
No
No
0
0
0xFFFF
–
PnCFE
603F hex
0
Error code
UINT
RO
Yes
No
–
–
–
–
PnB10
6040 hex
0
Controlword
UINT
RW
Yes
No
0
0
0xFFFF
–
PnB11
6041 hex
0
Statusword
UINT
RO
Yes
No
–
–
–
–
PnB12
605A hex
0
Quick stop option
code
INT
RW
No
Yes
2
0
4
–
PnB13
605B hex
0
Shutdown option
code
INT
RW
No
Yes
0
0
1
–
PnB14
605C hex
0
Disable operation
option code
INT
RW
No
Yes
1
0
1
–
PnB15
605D hex
0
Halt option code
INT
RW
No
Yes
1
0
4
–
PnB16
605E hex
0
Fault reaction option
code
INT
RW
No
Yes
0
0
0
–
PnB17
6060 hex
0
Modes of operation
SINT
RW
Yes
Yes
0
0
10
–
PnB18
Continued on next page.
Continued from previous page.
Index
Subin-
dex
Name
Data
Type
Ac-
cess
PDO
Map-
ping
Saving to
EEPROM
*1
Default
Value
Lower Limit Upper Limit Unit
Parame-
ter No.
*2