14.16 Digital Inputs/Outputs
14-47
14
Object Dictionary
14.16
Digital Inputs/Outputs
Digital Inputs (60FD Hex)
This object gives the status of the
digital inputs
to CN1 on the SERVOPACK.
Data Description
Index
Subin-
dex
Name
Data
Type
Access
PDO
Mapping
Value
Saving to
EEPROM
60FD hex
0
Digital inputs
UDINT
RO
Yes
−
No
Bit
Signal
Description
0
N-OT: Negative limit switch
0: OFF, 1: ON
1
P-OT: Positive limit switch
0: OFF, 1: ON
2
Home switch
0: OFF, 1: ON
3 to 15
−
Reserved.
16
SI0
0: OFF (open),
1: ON (closed)
17
SI1
0: OFF (open),
1: ON (closed)
18
SI2
0: OFF (open),
1: ON (closed)
19
SI3
0: OFF (open),
1: ON (closed)
20
SI4
0: OFF (open),
1: ON (closed)
21
SI5
0: OFF (open),
1: ON (closed)
22
SI6
0: OFF (open),
1: ON (closed)
23
−
Reserved.
24
HWBB1
Hardwired base block signal input 1
(0: Open, 1: Closed)
25
HWBB2
Hardwired base block signal input 2
(0: Open, 1: Closed)
26 to 31
−
Reserved.